ACS/ACC/ACP 604/607 Frequency ConvertersA-1Appendix A – ACS/ACC/ACP 604/607 Technical DataIEC Ratings The IEC ratings ratings for ACx 604 and ACx 607 with 50 Hz and 60 Hzsupplies are below. ACx = ACS/ACC/ACP. The ACx 607 is housed in aDrives-MNS cabinet. The ACx 604 is to be installed in a cabinet by theuser. The 690 V series and 2 x R8 and 2 x R9 frame sizes are notavailable for ACP 600. See next page for symbols.FrequencyConverterTypeNormal Use Heavy-duty UseFrameTypeDuty Cycle1/10 minDuty Cycle1/10 minDuty Cycle 1)2/15 sI 2N9/10min[A]I2Nmax1/10min[A]S N[kVA]P N[kW]P N[HP]I 2hd9/10min[A]I2hdmax1/10min[A]I2hd13/15s[A]I2hdmax2/15s[A]S hd[kVA]P hd[kW]P hd[HP]Three-phase supply voltage 380 V, 400 V or 415 VACx 604/607-0100-3 147 162 100 75 100 112 168 112 224 70 55 75 R7ACx 604/607-0120-3 178 196 120 90 125 147 221 147 294 100 75 100ACx 604/607-0140-3 216 238 140 110 150 178 267 178 356 120 90 125 R8ACx 604/607-0170-3 260 286 170 132 200 216 324 216 432 140 110 150ACx 604/607-0210-3 316 348 210 160 250 260 390 260 520 170 132 200ACx 604/607-0260-3 395 435 260 200 300 316 474 316 632 210 160 250 R9ACx 604/607-0320-3 480 528 320 250 350 395 593 395 790 260 200 300ACx 604/607-0400-3 600 661 400 315 400 494 741 494 988 320 250 350 2xR8ACx 604/607-0490-3 751 827 490 400 500 600 901 600 1200 400 315 400 2xR9ACx 604/607-0610-3 912 1003 610 500 600 751 1127 751 1502 490 400 500Three-phase supply voltage 380 V, 400 V, 415 V, 440 V, 460 V, 480 V or 500 VACx 604/607-0120-5 135 149 120 90 100 112 168 112 224 100 75 75 R7ACx 604/607-0140-5 164 180 140 110 125 135 203 135 270 120 90 100ACx 604/607-0170-5 200 220 170 132 150 164 246 164 328 140 110 125 R8ACx 604/607-0210-5 240 264 210 160 200 200 300 200 400 170 132 150ACx 604/607-0260-5 300 330 260 200 250 240 360 240 480 210 160 200ACx 604/607-0320-5 365 402 320 250 300 300 450 300 600 260 200 250 R9ACx 604/607-0400-5 460 506 400 315 350 365 548 365 730 320 250 300ACx 604/607-0490-5 570 627 490 400 500 456 684 456 912 400 315 400 2xR8ACx 604/607-0610-5 694 764 610 500 600 570 855 570 1140 490 400 500 2xR9ACx 604/607-0760-5 874 961 760 630 700 694 1041 694 1388 610 500 600Three-phase supply voltage 525 V, 550 V, 575 V, 600 V, 660 V or 690 VACx 604/607-0100-6 88 97 100 75 100 65 98 65 98 70 55 75 R7ACx 604/607-0120-6 105 116 120 90 125 88 132 88 132 100 75 100ACx 604/607-0140-6 127 140 140 110 150 105 158 105 158 120 90 125 R8ACx 604/607-0170-6 150 165 170 132 150 127 191 127 191 140 110 150ACx 604/607-0210-6 179 197 210 160 200 150 225 150 225 170 132 150ACx 604/607-0260-6 225 248 260 200 250 179 269 179 269 210 160 200ACx 604/607-0320-6 265 292 320 250 300 225 338 225 338 260 200 250 R9ACx 604/607-0400-6 351 386 400 315 350 265 398 265 398 320 250 300ACx 604/607-0490-6 428 470 490 400 450 340 511 340 510 400 315 350 2 x R8ACx 604/607-0610-6 504 555 610 500 500 428 642 428 642 490 400 450 2 x R9ACx 604/607-0760-6 667 734 760 630 700 504 756 504 756 610 500 500