Appendix A – ACS/ACC/ACP 604/607 Technical DataACS/ACC/ACP 604/607 Frequency ConvertersA-5Efficiency andCoolingEfficiency: Approximately 98 % at nominal power levelCooling Method: Internal fan, flow direction from the bottom to the topAmbient Conditions Environmental limits of the ACS/ACS/ACP 600 frequency convertersare given below. The frequency converters are to be used in a heated,indoor, controlled environment.1) At sites over 1000 m (3300 ft.) above sea level, the maximum output current isderated 1% for every additional 100 m (330 ft.). If the installation site is higher than2000 m (6600 ft.) above sea level, please contact your local ABB distributor or office forfurther information.2) See subsectionOutput Current Temperature Derating on page A-3.Fuses Input fuse ratings of the ACS/ACC/ACP 607 and recommended inputfuse ratings of the ACS/ACC/ACP 604 are below. A minimum ratedcurrent in amperes, A 2s maximum I 2t value, V rated voltage in volts.Only ultra rapid fuses guarantee proper protection for the rectifiersemiconductors.ACS/ACC/ACP 600 Operationinstalled for stationary useStoragein the protective packageTransportationin the protective packageInstallation SiteAltitudeNominal output power at0 to 1000 m (3300 ft) abovesea level 1)- -Air Temperature 0 to +40 °C (32 to 104°F)2)(IP 21/22 and ACx 607, IP 54)0 to +25 °C (32 to 77°F) 2)(ACx 601, IP 54)-40 to +70 °C (-40 to +158°F) -40 to +70 °C (-40 to +158°F)Relative Humidity 5 to 95% Max. 95% Max. 95%No condensation allowed. Maximum allowed relative humidity is 60% in the presence ofcorrosive gases.ContaminationLevels(IEC 721-3-3)No conductive dust allowed.Boards without coating:Chemical gases: Class 3C2Solid particles: Class 3S2Boards with coating:Chemical gases: Class 3C3Solid particles: Class 3S2Boards without coating:Chemical gases: Class 1C2Solid particles: Class 1S3Boards with coating:Chemical gases: Class 1C2Solid particles: Class 1S3Boards without coating:Chemical gases: Class 2C2Solid particles: Class 2S2Boards with coating:Chemical gases: Class 2C2Solid particles: Class 2S2AtmosphericPressure70 to 106 kPa0.7 to 1.05 atmospheres70 to 106 kPa0.7 to 1.05 atmospheres60 to 106 kPa0.6 to 1.05 atmospheresVibration(IEC 68-2-6)Max. 0.3 mm (0.01 in.)(2 to 9 Hz),max. 1 m/s2 (3.3 ft./s2)(9 to 200 Hz) sinusoidalMax. 1.5 mm (0.06 in.)(2 to 9 Hz),max. 5 m/s2 (16.4 ft./s2)(9 to 200 Hz) sinusoidalMax. 3.5 mm (0.14 in.)(2 to 9 Hz),max. 15 m/s2 (49 ft./s2)(9 to 200 Hz) sinusoidalShock(IEC 68-2-29)Not allowed Max. 100 m/s2 (330 ft./s2),11 msMax. 100 m/s2 (330 ft./s2),11 msFree Fall Not allowed 250 mm (10 in.) for weightunder 100 kg (220 lbs.)100 mm (4 in.) for weight over100 kg (220 lbs.)250 mm (10 in.) for weightunder 100 kg (220 lbs.)100 mm (4 in.) for weight over100 kg (220 lbs.)