Technical data100Prevention of Unexpected Start: AGPS-21 boardNominal input voltage 115 VAC or 230 VACInput voltage range(selected by jumper)95...132 VAC (X3 on), 185...265 VAC (X4 on, default)Nominal frequency 50/60 HzCurrent 0.77 A at 115 V, 0.44 A at 230 VMax. external fuse 16 AInput connector X1 3 ◊ 2.5 mm2User connector 1, 2, 3 600 V, 25 A, 0.5...4 mm 2 (20...12 AWG)Output voltage 24 V + 0.5 VNominal output current 1.7 A (50 ∞C, 122 ∞F)X2 terminal block type JST B3P-VHAmbient temperature 0...50 ∞C (32...122 ∞F)Relative humidity 30...90%, no condensation allowedApprovals CE, C-UL US listedAmbient conditionsEnvironmental limits for the drive are given below. The drive is to be used in a heated,indoor, controlled environment.Operationinstalled for stationary useStoragein the protective packageTransportationin the protective packageInstallation site altitude 0 to 4000 m (13123 ft) abovesea level [above 1000 m(3281 ft), see sectionDerating]- -Air temperature -15 to +50 ∞C (5 to 122 ∞F).No frost allowed. Seesection Derating.-40 to +70 ∞C (-40 to+158 ∞F)-40 to +70 ∞C (-40 to+158 ∞F)Relative humidity 5 to 95% Max. 95% Max. 95%No condensation allowed. Maximum allowed relative humidity is 60% in the presence ofcorrosive gases.Contamination levels(IEC 60721-3-3, IEC 60721-3-2, IEC 60721-3-1)No conductive dust allowed.Boards without coating:Chemical gases: Class 3C1Solid particles: Class 3S2Boards with coating:Chemical gases: Class 3C2Solid particles: Class 3S2Boards without coating:Chemical gases: Class 1C2Solid particles: Class 1S3Boards with coating:Chemical gases: Class 1C2Solid particles: Class 1S3Boards without coating:Chemical gases: Class 2C2Solid particles: Class 2S2Boards with coating:Chemical gases: Class 2C2Solid particles: Class 2S2Atmospheric pressure 70 to 106 kPa0.7 to 1.05 atmospheres70 to 106 kPa0.7 to 1.05 atmospheres60 to 106 kPa0.6 to 1.05 atmospheresVibration (IEC 60068-2) Max. 1 mm (0.04 in.)(5 to 13.2 Hz),max. 7 m/s 2 (23 ft/s2)(13.2 to 100 Hz) sinusoidalMax. 1 mm (0.04 in.)(5 to 13.2 Hz),max. 7 m/s2 (23 ft/s2)(13.2 to 100 Hz) sinusoidalMax. 3.5 mm (0.14 in.)(2 to 9 Hz),max. 15 m/s 2 (49 ft/s 2)(9 to 200 Hz) sinusoidalShock (IEC 60068-2-29) Not allowed Max. 100 m/s2 (330 ft./s 2),11 msMax. 100 m/s2 (330 ft./s 2),11 msFree fall Not allowed 100 mm (4 in.) for weightover 100 kg (220 lb)100 mm (4 in.) for weightover 100 kg (220 lb)