Contents - EFFECTIVE: 2018
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table of contents
- What this chapter contains
- General safety in installation, start-up and maintenance
- Electrical safety in installation, start-up and maintenance
- Additional instructions and notes
- Grounding
- Additional instructions for permanent magnet motor drives
- General safety in operation
- Purpose of the supplement
- Layout of option +P940 (IP20, UL Open Type)
- Layout of option +P944 (IP20, UL Open Type)
- Planning the layout of the cabinet
- Arranging the grounding inside the cabinet
- Planning the attaching of the cabinet
- Planning the cooling
- Minimum air inlet and outlet grating sizes
- Installing drives above one another
- Required free space
- Planning the use of cubicle heaters
- Examining the installation site
- Unpacking and examining the delivery (frames R1 to R2)
- Unpacking and examining the delivery (ACS880-11 and ACS880-31 frame R3)
- Unpacking and examining the delivery (ACS880-01 frames R3 to R5)
- Unpacking and examining the delivery (ACS880-01 frames R6 to R9)
- Unpacking and examining the delivery (ACS880-11 and ACS880-31 frames R6 to R9)
- Installing the drive
- Checking the insulation of the assembly
- Power cable connection procedure (IEC)
- Connecting the control cables – ACS880-01 frames R1 and R2
- Installing the drive module shelves and connecting the cables – ACS880-01 frame R3
- Connecting the control cables – ACS880-01 frame R3
- Connecting the control cables – ACS880-01 frames R4 and R5
- Connecting the control cables - ACS880-01 frames R6 to R9
- Degree of protection
- R1 (Option +P940, IP20, UL Open Type)
- R1 (Option +P944, IP20, UL Open Type)
- R2 (Option +P940, IP20, UL Open Type)
- R2 (Option +P944, IP20, UL Open Type)
- R3 (Option +P940, IP20, UL Open Type)
- R3 (Option +P944, IP20, UL Open Type)
- R4 (Option +P940, IP20, UL Open Type)
- R4 (Option +P944, IP20, UL Open Type)
- R5 (Option +P940, IP20, UL Open Type)
- R5 (Option +P944, IP20, UL Open Type)
- R6 (Option +P940, IP20, UL Open Type)
- R6 (Option +P944, IP20, UL Open Type)
- R7 (Option +P940, IP20, UL Open Type)
- R7 (Option +P944, IP20, UL Open Type)
- R8 (Option +P940, IP20, UL Open Type)
- R8 (Option +P944, IP20, UL Open Type)
- R9 (Option +P940, IP20, UL Open Type)
- R9 (Option +P944, IP20, UL Open Type)
- R3 – Option +P940 (IP20, UL Open Type)
- R6 – Option +P940 (IP20, UL Open Type)
- R8 – Option +P940 (IP20, UL Open Type)
|
Mechanical installation 43Unpacking and examining the delivery (ACS880-01 framesR3 to R5)This illustration shows the layout of the transport package. Examine that all items arepresent and there are no signs of damage. Read the data on the type designationlabel of the drive to make sure that the drive is of the correct type.Item Description Item Description1 Cable box package 6 Straps2 Drive 7 Pallet3 Printed quick guides and manuals,multilingual residual voltage warningsticker and manuals CD inside thebox8 Control panel selected in the order (ina separate package) in the option box.4 Cardboard box. Mounting templatein the cardboard box.9 Possible options in separatepackages, if they have been orderedwith a plus code.5 StopperTo unpack:• Cut the straps (6).• Remove the cardboard box (4) and option box (3).• Remove the stopper (5).• Lift the drive.54123
PreviousNext |