2.9.4 Installation of DeviceNet I/O, Gateways and encoder interface units, IRC5LocationThe DeviceNet I/O units, Gateway or encoder interface units to be installed areshown in the illustration below.ABCxx0600003256I/O units, Gateways or Encoder interface unitsAMounting railBConnection terminal XT31CRequired equipmentNoteArticle numberEquipmentDeviceNet I/O units, Gateways or en-coder interface units3HAC050992-001Application manual - DeviceNet Mas-ter/SlaveSee Circuit diagrams onpage 249.Circuit diagramFittingThe procedure below details how to fit the units.Note/IllustrationActionDANGERBefore commencing any work inside thecabinet, please observe the safety inform-ation in section Make sure that the mainpower has been switched off on page 25.1Fit the DeviceNetI/O unit by snapping itonto the mounting rail.2Connect the DC supply to the board.3Described in the Application manual forthe respective busses.Connect wires to the inputs and outputconnectors as required.4Product manual - IRC5 Panel Mounted Controller 1113HAC047137-001 Revision: J© Copyright 2007-2018 ABB. All rights reserved.2 Installation and commissioning2.9.4 Installation of DeviceNet I/O, Gateways and encoder interface units, IRC5