CommandsTable 7:Command push buttonsName DescriptionMenu • Moving directly to the Main Menu, if currently in default view or in any menu.• Moving to the default view, if currently in Main Menu.R/L Changing the control position (remote or local) of the device.• When the R LED is lit, remote control is enabled and local control disabled.• When the L LED is lit, local control is enabled and remote control disabled.• When none of the LEDs are lit, both control positions are disabled.Clear Activating the Clear/Reset view.Help Showing context sensitive help messages.3.5.4 LHMI functionality3.5.4.1 Protection and alarm indicationProtection indicatorsProtection indicator LEDs are called Ready, Start and Trip.Table 8:Ready LEDLED state DescriptionOff Auxiliary supply voltage is disconnected.On Normal operation.Blinking Internal fault has occurred or the IED is in test mode. Internal faults areaccompanied by an indication message.Table 9:Start LEDLED state DescriptionOff Normal operation.On A protection function has started and an indication message is displayed.• If several protection functions start within a short time, the last start isindicated on the display.Blinking A protection function is blocked.• The blocking indication disappears when the blocking is removed orwhen the protection function is reset.Section 3 1MRS756499 ARED615 overview22 RED615Operation Manual