2CCF018900R0002-CH | AC Ladestation für Elektrofahrzeuge, Modell eCharger 23Change from two to one column8 SignalmeldungenWICHTIG (HINWEIS)Die Signalmeldungen der LED-Anzeige und des Tastenausgangs (LED in der Taste „Start/Stopp“) zeigen evtl.vorhandene Störungen und den Systemzustand an.Die für die Behebung möglicher Störungen gemachten Angeben richten sich an Fachpersonal.Abb. 30: Rote LEDs signalisieren FehlerLED Description—SolutionGreen Ready to chargeBlue Charging at maximum speedBlue/Red Charging at reduced speed or stopped due to overtemperatureRed 1x RCD fault—contact local electricianRed 2x Charging station blocked—contact local operatorRed 3x Detected card id unknown—Register at abb.e-track2.nlRed 4x Detected card id for transaction stop mismatchRed 5x Card not accepted because customer is blockedRed 6x PP value underrated—try another charging cableRed 7x State D (lead battery) detected— This is not supportedRed 8x CP state unknown—try another charging cableRed 9x CP diode not detected—try another charging cableRed 10x PP state unknown—try another charging cableRed 11x Boot process active—please wait...Red 12x Generic error—contact supportRed 13x CP not connected (state A)Red 14x PP not connectedRed 15x Lock failedRed 16x Serial KWH meter faultRed 17x Fuse trippedRed 18x Second RCD tripped—contact local electricianRed 19x Relay fault—contact local electricianRed 20x Card expired —contact local operatorRed 21x Cable reconnect detected—not allowed