ADJ Products, LLC - www.adj.com - Hydro Beam X1 User Manual Page 15Hydro Beam X1 Torque Settings & IP Tester1 Lens Assembly to Head Casting (x6) 6.5-8.7 In-Lb / 3mm Hex2 Lamp Cover to Head Casting (x4) 6.5-8.7 In-Lb / 3mm Hex3 Yoke Arm Cover to Yoke Frame (8 x Each Side = 16 Total) 6.5-8.7 In-Lb / 3mm Hex4 Access Cover to Yoke Frame (x4) Manual Screwdriver / 3mm Hex5 Handle to Base Casting (2 x Each Side = 4 Total) Fasten by Air Screwdriver / 5mm Hex6 Bottom Cover to Base Casting (x12) 6.7-9.6 In-Lb / #2 Phillips7 Power & Data Connector to Base Casting (x10) 6.5-8.7 In-Lb / #2 Phillips8 1/4 Turn Adaptor Plate to Bottom Cover (x14) 6.5-8.7 In-Lb / #2 PhillipsSCREW LOCATIONS TORQUE SETTING & TOOL SIZE#TORQUE SETTINGS FOR SCREWSALL SCREWS MUST BE TIGHTENED WITH A TORQUE DRIVER. All screws are AllenHead screws. Please see below for screw locations, screw quantity and torque settings. Thenumber listed in the “#” column corresponds to the location on the fixture. See the fixturediagram and number on the next page for screw location depictions.CAUTION! DO NOT OVER TORQUE SCREWS AS THIS CAN CAUSE LEAKAGE ISSUES!TO CONFIRM THE IP65 INTENGRITY AFTER A LAMP REPLACEMENT, TEST THE FIXTUREUSING THE ELATION IP TESTER. CONTACT ELATION SERVICE FOR MORE DETAILS.TORQUE DRIVERS (Recommended):UTICA TS-30 (Shown)ALTERNATIVE DRIVERS:Proto J6107AWiha 28887