1Section 61245201L1-5, Issue 361245201L1-5CFNID and T200 FNIDFractional T1 Network Interface DeviceInstallation and MaintenanceCONTENTS1. GENERAL ............................................................................ 12. INSTALLATION .................................................................. 23. CONNECTIONS ................................................................... 34. DSL SYSTEM TESTING .................................................... 45. CONTROL PORT OPERATION ......................................... 46. DSL DEPLOYMENT GUIDELINES ................................. 117. TROUBLESHOOTING PROCEDURES ........................... 128. MAINTENANCE ................................................................ 129. PRODUCT SPECIFICATIONS .......................................... 1210. WARRANTY AND CUSTOMER SERVICE .................... 12Appendix A. FT1 Loopbacks ................................................... A-1FIGURESFigure 1. ADTRAN FNID ...................................................... 1Figure 2. FNID Option Switch Locations .............................. 2Figure 3. FNID Network Loop Connection Locations .......... 4Figure 4. RS-232 (DB9) Pin Assignments ............................. 4Figure 5. Introductory Menu Screen ...................................... 7Figure 6. HDSL Main Menu Screen ...................................... 7Figure 7. Current System Status Screen ................................. 8Figure 8. Performance History Screen ................................... 8Figure 9. Loopback Options Screen ....................................... 9Figure 10. Self Test Options Screen ........................................ 9Figure 11. Provisioning Options Screen ................................. 10Figure 12. Troubleshooting Screen ......................................... 10Figure 13. DSL Deployment Guidelines ................................. 11Figure A-1. FT1 Loopbacks .................................................... A-1Figure A-2. FT1 DP Network Loopback ................................. A-1Figure A-3. FT1 DP CPE Loopback ....................................... A-1Figure A-4. FT1 Repeater #1 or # 2 Network Loopback ........ A-2Figure A-5. FNID Network Loopback .................................... A-2Figure A-6. FNID CPE Loopback ........................................... A-2TABLESTable A. Front Panel Functions ............................................. 3Table B. FNID Card Edge Pin Definitions ........................... 3Table C. Definition of Screen Abbreviations ........................ 5Table D. Loop Insertion Loss Data ....................................... 11Table E. Troubleshooting Guide .......................................... 12Table F. FNID Unit Specifications ...................................... 13Table A-1. FT1 Loopback Select Codes ................................ A-31. GeneralThis practice is an installation and maintenance (I/M)guide for the ADTRAN Fractional T1 NetworkInterface Device (FNID). Figure 1 is an illustration ofthe ADTRAN FNID.Revision HistoryThis practice has been reissued to reflect additionalsupport detail for two FT1 repeater applications.The ADTRAN FNID is a network terminating unitused to deploy a fractional T1 circuit using 2-wiremetallic facilities on CSA loops. This practice iswritten to support both the T200 FNID circuit pack(P/N 1245201L1) and the FNID standalone(P/N 4245201L1) units.The FNID is housed in a standalone metal enclosure.The T200 FNID card plugs into a standard Type200/400 multiple mounting shelf.Section 61245201L1-5CIssue 3, September 1999CLEI Code: NCDIFBH4 _ _Trademarks: Any brand names and product names included in this document aretrademarks, registered trademarks, or trade names of their respective holders.Figure 1. ADTRAN FNIDDSLFNID1245201L1DS1SFAMI(GRN)(GRN)ESFB8ZS(YEL)(YEL)LBKLOCLBKREMRS232TXRXMON