10Base-T Hub Installation and Maintenance Practice4 61181012L1-5CComplianceCAUTIONElectrostatic discharge (ESD) can damage electronic modules.When handling modules, wear an antistatic discharge wrist strapto prevent damage to electronic components. Place modules inantistatic packing material when transporting or storing. Whenworking on modules, always place them on an approved antistaticmat that is electrically grounded.Figure 2 shows the compliance codes for the 10Base-T Hub. The 10Base-T Hub is NRTL-listedto the applicable standards. It meets or exceeds all the applicable requirements of NEBS,Telcordia GR-63-CORE, and GR-1089-CORE.The 10Base-T Hub is intended for deployment in Central Office (CO) type facilities, EEEs,EECs, and locations where the NEC applies.CAUTIONPer GR-1089-CORE, the 10Base-T Hub is designed and intendedfor installation as part of a Common Bonding Network (CBN). The10Base-T Hub is not designed nor intended for installation as partof an Isolated Bonding Network (IBN).CAUTIONPer GR-1089-CORE Section 9, the 10Base-T Hub is designed andintended only for installation in a DC-C (common) bonding andgrounding system. The 10Base-T Hub is not intended or designedfor installation in a DC-I (isolated) bonding and grounding system.NOTEThe 10Base-T Hub (P/N 1181012L1) does not require the use of anexternal AC Surge Protection Device. However, for highly exposedAC mains environments, an external AC Surge Protection Device isrecommended.Table 2. Compliance CodesCode Input OutputPower Code (PC) A –Telecommunication Code (TC) – XInstallation Code (IC) F C