The manufacturer refusesto be held responsible, ifthese safety measures arenot abided by.Supply connectionsThis hob has to be connected to 220-240V (~ 50-60 Hz ) electricity supply.The hob has a terminal block which ismarked as follows:• L — Live terminal• N — Neutral terminal• or E — Earth terminalBefore carrying out the connection,make sure:1. The limiter valve and the electricalsystem can take the appliance load(see the rating plate)2. The supply system is equipped withan efficient earth connection incompliance with the currentstandards and regulations3. The outlet or omnipolar switch usedfor connection is easily accessiblewith the appliance installed.The appliance is supplied with a 3 coreflexible power cable with a 3 amp plug. Ifit is necessary to change the fuse, use a 3amp ASTA-approved (BS 1362) fuse.A BCDEA. Green and YellowB. 3 amp fuseC. BrownD. Cord clampE. BlueThe wires in the cord are coloured asfollows:Green and yellow - EarthBlue - NeutralBrown - LiveWARNING!A cut off plug inserted into a13 amp socket is a seriousshock hazard. Ensure thatthe cut off plug is disposedof safely.3.7 Replacement of theconnection cableThe replacement of electriccable must be carried outexclusively by the serviceforce centre or by personnelwith similar competencies, inaccordance with the currentregulations.To replace the connectioncable use only H03V2V2-FT90 or equivalent type.Make sure that the cablesection is applicable to thevoltage load and theworking temperature. Theyellow/green earth wire (B)must be approximately 2 cmlonger than the live andneutral wire (A).A B1. Connect the green and yellow (earth)wire to the terminal which is markedwith the letter 'E', or the earthsymbol , or coloured green andyellow.www.aeg.com10