Ascotel® IntelliGate® 150/300 as of I7.9176 Operation and Maintenancesyd-0210/1.7 – I7.9 – 12.20096. 4 Generation Change6. 4. 1 System UpgradeAll that is required to upgrade a system is new system software. The system up-grade can be carried out on site or remotely with a version transfer.1. Initiate the upload process as described in the paragraph "Initiating an uploadprocess", page 162. Select "Start Now" as the activation time.2. Once the upload is completed, the PBX resets and is then ready to operate againwith the new system software and the usual system configuration.Notes:– AIMS 7.6 and higher uses the Microsoft SQL Server database for itsdata management. Borland Paradox was used up until AIMS 7.5.During the AIMS 7.6 installation process the existing data stock ofthe Borland Paradox database is transferred to the Microsoft SQLServer database and adapted. The existing Paradox database is pre-served. Only generation >= I7.0 PARADOX databases can be trans-ferred. The Paradox database can also be subsequently imported.The relevant instructions can be found in the AIMS Help. Please alsorefer to the version notes for AIMS 7.6 in the readme.txt file.– An Aastra 5370ip logged on to the system as an Office 35IP prior tothe upgrade to I7.5 (= Office 70IP-b) can still be used. If the terminalis logged on to the system as an Aastra 5370ip a software update isautomatically initiated. One licence per terminal is required to oper-ate the IP system terminals.