User’s Guide104Setting a SCSI Channel’s Secondary ID / DriveChannelPress ENT for two seconds to enter theMain Menu. Press t or s to select "Viewand Edit SCSI Channels", then pressENT.SCSI channel information will bedisplayed on the LCD. Press ENT on thedrive channel you wish the SCSI IDchanged.Press t or s to select “Set SCSIChannel Secondary ID”, then press ENT.The current Secondary SCSI ID will bedisplayed on the LCD. Press t or s tochange the current SCSI ID, then pressENT for two seconds.• Every time you change a channel’s SCSI ID, youmust reset the controller for the changes to takeeffect.• The default SCSI ID of the Host channel is 0, theDrive channel is 7.• If only one controller exist, you must set theSecondary Controller’s SCSI ID to “NA”. If asecondary controller exist, you need to set aSCSI ID.• Multiple SCSI ID can be applied to the Hostchannel while the Drive channel, one SCSI ID orno SCSI ID.• Multiple SCSI ID is supported in firmware version2.11 or later. Firmware versions earlier than 2.11only supports one SCSI ID.• At least a controller’s SCSI ID has to be presenton the SCSI bus.View and EditSCSI Channels ◊CH1=Drive PID=7SID=NA SXF=20.0MSet SCSI ChannelSecondary ID ..Set Sec. CtlrID= 7 to ID: 8 ?