ENsigfox DRY CONTACTS- Guide utilisateur / User guide version V1.2.055Page of 802.2.4 Control of the product output(s)The product allows you to configure all or a part of the digital connections as outputs to control them from the network by a downlink frameaccording to the following diagram:The settings associated with this mode of operation are:• The configurations of the different digital inputs (registers 302 to 305).A complete list of the registers can be found in paragraph 3.4.E.g.:Register Value encoding Value ResultS302 Hexadecimal 0x73 Input TOR1 configuration:• Periodic mode• Detection of high and low edges• Waiting* period of 1 secondS303 Hexadecimal 0x07 Input TOR2 configuration:• Output (Default state = 1/close)• No waiting* periodS304 Hexadecimal 0xB4 Input TOR3 configuration:• Event mode• Detection of high edges only• Waiting* period of 20 secondS305 Hexadecimal 0x32 Input TOR4 configuration:• Periodic mode• Counting of low edges only• Waiting* period of 50 millisecondsIn this example TOR2 is configured as an output with a state by default at 1.Product in standbyFrame send 0xXXReception frame 0x03Updating the digitalinputs states configu-red as outputEvent orperiodereached ?YesNo