ENsigfox DRY CONTACTS- Guide utilisateur / User guide version V1.2.065Page of 804.1.3 Network configuration data framesFollowing reception of a downlink frame with the code 0x02 or on switching to the operating mode (from the Park or Command Mode), thenext frame (0x20) representing the network configuration of the product is transmitted:0 1 2 3 4 5 6 7 8 9 10Code Status PAYLOAD0x20 Cf status 202 X X X X X X X X0x20 0xA3 0x02Description of the frame:• Byte 2 : register 302, nomber of repetitionIn the example in grey this gives:• Byte 2=0x02: the nomber of repetition will be 2This frame (0x30) is only issued when the different digital outputs are configured in the event mode or in output and at the frequency definedby register 300.0 1 2 3 4 5 6 7 8 9 10Code Status PAYLOAD0x30 Cf Status X X X X X X X0x30 0xABAs the example shows it only contains the value of the status byte.4.1.4 Data FrameThis frame (0x42) contains the values measured on the different digital outputs.0 1 2 3 4 5 6 7 8 9 10Code Status PAYLOAD0x40 Cf Status Informations TOR1 Informations TOR2 Informations TOR3 Informations TOR4 Détails0x40 0xAB 0x00F1 0x0002 0x0001 0x0000 0x9CDescription of the frame:• Byte 2 and 3: Information on the TOR1• If configured as an input (event or Periodic mode): these bytes contain the value of the event counter of Input TOR1• If configured as an output: current state of the output TOR1• Byte 4 and 5: Information on TOR2• If configured as an input (event or Periodic mode): these bytes contain the value of the event counter of Input TOR2• If configured as an output: current state of the output TOR2• Byte 6 and 7: Information on TOR3• If configured as an input (event or Periodic mode): these bytes contain the value of the event counter of Input TOR3• If configured as an output: current state of the output TOR3