NAM-TRS372-MT-EN-C p35/38The information in this document is the property of Automatic Systems and is confidential. The consignee withholds from using it for anything other than the use of the products orthe execution of the project to which they belong and withholds from communicating it to third parties without prior written agreement from Automatic Systems. Document subject tochange without prior notice.5. TROUBLESHOOTINGTurnstile out of service. See messages on the control board display ("OPERATION" group, "Status"parameter).Friction is perceptibleduring movements.The bolts and/or rollers may be jammed, especially in harsh environments(e.g., in a sea environment). Use a silicon spray on parts that need to bereleased.Obstacle cannot beunlocked.Leave 1 to 2 mm gap between the connecting rod (B) of the electromagnetand the bolt stem (D) (setting the length of the connecting rod by means ofnuts P and Q) in order to create an impact with the bolt when theelectromagnet is activated.The electromagnets may be blocked if tightenedtoo firmly. Slightly loosen nut (Q) in order todecompress spring (C).Spring (C) does not have the energy necessary to pull the bolt. Compressthe spring by tightening nut (Q) or replace it.Obstacle cannot belocked.Bolt release spring (K) is loose. Retighten thespring by adding a few turns to it.P B D1 to 2 mmDBQQ CK