AXIS F44 Main UnitHardware OverviewNoteThe Network LED can be disabled so that it does not flash when there is network traffic. To configure, go to Setup > SystemOptions > Ports & Devices > LED. See the online help for more information.Network LED IndicationGreen Steady for connection to a 100 Mbit/s network. Flashes for network activity.Amber Steady for connection to a 10 Mbit/s network. Flashes for network activity.Unlit No network connection.Power LED IndicationGreen Normal operation.Amber Flashes green/amber during firmware upgrade.Shorten Sensor Unit CableNoteThe sensor unit’s cable cannot be extended.The sensor unit is delivered with a cable. To shorten the cable follow these steps:1. Cut the cable to the desired length. Measure from the sensor unit.2. Strip the plastic outer coating from the end of the cable.3. Peel back the shield.4. Flatten the colored wires in the order described below.1 Brown2 White/brown3 Not used4 Not used5 White/blue6 Blue5. Insert the wires all the way into a shielded 6P6C RJ12 connector.NONONOTICETICETICEMake sure that the wires stay in the correct order and that the cable shield makes good contact with the connector shield.6. Use a crimping tool to fasten the connector to the cable.8