PCA OperationPress ENTER to save the selected character and advance to the next posi-tion. If you make a mistake, press ENTER until the cursor is over the wrongcharacter and make your correction by again using the st keys.After all the desired characters have been selected, press RUN to save thetext line and return to the initial User Name Screen.Front Panel Key Functions for Individual User Name Screens:– Increment character– Decrement character– Select the displayed character and advance to the nextcharacter position– Save the text line and return to the initial User Name Screen– Abort any changes to the text line and return to the initialUser Name Screen4.23 Saving Test DataO2 4.0 CO 12 HLD DRAFTC2 9.5 NX 15 NG DRAFT – 0.25 WCTA 68.0 TS 374 P HOT SPOT 374 °F PEF 82.6 EA 21 «S « STo save the data displayed in either the Combustion Test or DraftScreen, first use the st keys to move the cursor ( z ) in front of the save (S )function and then press the ENTER key. The displayed data will be saved inmemory, and can be recalled at a later time for viewing from the MemoryDirectory Screen (Section 4.10).NOTE: Data will be automatically stored in the next freememory location. After all memory locations are filled, anyadditional data that is saved will start overwriting datastarting at the first memory location.Instruction 0024-9219 4-29