62Options: SameAsTriggerQuantity BothmaxReportCells Maximum number of IRAT cells that can be included in ameasurement report.Range: 1 to 8reportInterval Report Interval of the periodic measurement report, inmilliseconds.Options: 120 (default), 240, 480, 640, 1024, 2048, 5120,10240, 60000, 360000, 720000, 1800000, 3600000 msreportAmount Number of times an IRAT measurement report is sent.Options: 0,1,2,4,8,16,32measQuantityUtra Indicates the measurement quantity used for UTRA eventmeasurement evaluation or the measurement quantity to beincluded in the UTRA measurement report.Options: CPICH_RSCP CPICH_EcNoUTRAThresholdRsCP RSCP threshold to be used in UTRA measurement reporttriggering condition for event B2, per CPICH_RSCP in TS 25.133[29] for FDD and P-CCPCH_RSCP in TS 25.123 [30] for TDD.Range: -5 to 91UTRAThresholdEcNO Energy per Chip Noise (EcNo) threshold to be used in UTRAmeasurement report triggering condition for event B2, perCPICH_Ec/No in TS 25.133 [29] for FDD. The field is notpresent for TDD.Range: 0 to 49GERANThreshold Threshold to be used in the GERAN measurement reporttriggering condition for event B2. The actual value is IE value –110 dBm. Refer to 3GPP 36.331 6.3.5.Range: 0 to 63Figure 5-32: A3 Event Threshold