5.2.3 Mounting the Center- and Side-Mount BracketsEZLSA-MBK-11End Mount BracketEZLSA-MBK-11End Mount BracketEZLSA-MBK-12Center Mount BracketFigure 16. Mounting the center- and side-mount brackets• SeeSensor Mounting and Mechanical Alignment onpage 31 for additional mounting recommendations.• The machine interface connector ends of both sensorsmust point in the same direction.• The sensors are designed to be mounted with up to910 mm of unsupported distance between bracketswhen they are subject to shock or vibration .• Loosely mount the brackets to the desired surfaceusing the supplied M5 bolts and nuts, or user-suppliedhardware.• A simple "L" mounting bracket can be created by dis-assembling the EZLSA-MBK-11 and only using themounting flange.• SeeOptional Mounting Brackets on page 65 formounting bracket dimensions.1. From a common point of reference (ensuring the calculated minimum safety distance), measure to locate the emitterand receiver in the same plane, with their midpoints directly opposite each other, and locate and drill mountingholes if necessary.2. Attach the mounting flange of the EZLSA-MBK-12 to the mounting holes (back-mount only).3. Remove the channel nuts from the EZLSA-MBK-12 clamp and slide them into the side mounting channel. A smallpiece of adhesive tape can be use to temporarily location the nuts within the channel.4. Position the emitter and receiver and re-assemble the clamp to the channel nuts. Tighten when the sensor isproperly located.5. Rotate sensor(s) so that the windows directly face each other. Tighten the screw.6. Measure from a reference plane, for example, a level building floor, to the same point(s) on the emitter and receiverto verify their mechanical alignment. Use a carpenter’s level, a plumb bob, or the optional LAT-1 Laser AlignmentTool (seeAlignment Aids on page 67) or check the diagonal distances between the sensors, to achievemechanical alignment.7. Temporarily tighten all fasteners that allow for adjustment. Final alignment procedures are explained inInitialCheckout Procedure on page 35.5.2.4 EZLSA-MBK-16 Side-Mount BracketThe EZLSA-MBK-16 provides a mounting option that is adjustable (lateral and +15/-20° rotational) from the face of thesensor and allows "no blind zone" mounting with minimal or no "gaps" in detection. The bracket can be mounted to asurface on the back or the side of the sensor (not typically to be used in conjugation with EZLSA-MBK-11 end-mountbracket).EZ-SCREEN® LS Basic Safety Light Screen30 www.bannerengineering.com - Tel: 763.544.3164