Reading Parameters33TriggeredIf checked, it allows assigning a trigger through which the oscillating mirror can be activated to work in a secondreading zone according to the defined parameters.Second Zone TriggerThis parameters defines the number of the input or the phase working as trigger.Selections: Phase (available only when working in On Line operating mode)Input 1Input 2Second Zone Trigger LevelThis parameter allows setting the active state of the trigger. When the selected state is active, the oscillating mirrorstarts working in the second reading zone according to the parameters set:Selections: Active OpenActive ClosedSecond Zone Oscillating ModeThis parameter defines the oscillating mode of the scanner mirror to be used in the second reading zone:Selections: Fixed the oscillating mirror deflects the scan line at a fixed angle of deflection (-15°).Continuous the scan line is deflected according to the Second Zone Amplitude andSecond Zone Frequency settings.Second Zone Amplitude (degrees)This parameter is available only when working in Continuous Second Zone Oscillating Mode.It defines the deflection range in degrees as a symmetrical oscillation with respect to the fixed angle (-15°).Selections: a value from 10° to 40°:Second Zone Frequency (Hz)This parameter is available only when working in Continuous Second Zone Oscillating Mode.It defines the oscillating frequency in Hertz:Selections: a value from 0.5 to 4.0Hertz:NOTEThe maximum allowable frequency for an amplitude of 35° or more is 3 Hz.TCNM-SPLD-OM Oscillating MirrorNOTEThis parameter group is available only for TCNM-SP scanners (Oscillating Mirror models).Oscillating ModeThis parameter defines the oscillating mode of the scanner mirror: