Configuring the CameraBasler A500k Series 4-21PRELIMINARY4.2.5 Test Image CommandPurpose: To enable or disable a test image, and to select a test image. See Section 3.10 for anexplanation of the available test images.Type: This is a read or write command.Read Command: Cmd-ID R/W-Flag Data Length Data0xA1 1 1 -Response: Cmd-ID R/W-Flag Data Length Data0xA1 0 1 1 ByteWrite Command: Cmd-ID R/W-Flag Data Length Data0xA1 0 1 1 ByteResponse: NoneData Format: Byte 1 An ID that specifies the test image (see the table below).ID Test Image0x00 Image from sensor (standard mode)0x01 Gray Gradient Test Image0x02 Color Gradient Test Image (Bayer Pattern)0x03 Running Line Test Image0x04 White Screen Test Image