Configuring the Camera36 Basler IP Camera3.6 Alarm Handling ParametersThe parameters in the Alarm Handling group are used to select the sources that can declare analarm condition and to control the actions that will be taken when an alarm condition is declared.3.6.1 Alarm Sources SectionThe alarm sources section of the alarm handling parameters group is used to select the sourcesthat can declare an alarm condition.User Trigger TabSource Enable - Check the Source Enable box on the User Triggertab to enable the user trigger as a source for declaring an alarmcondition.Digital In TabSource Enable - Check the Source Enable box on the Digital In tabto enable the camera’s digital input line as a source for declaring analarm condition.If the digital input line is enabled as an alarm source and the linebecomes active, an alarm condition will be declared.Motion TabSource Enable - Check the Source Enable box on the Motion tab toenable motion detection as a source for declaring an alarm condition.If motion detection is enabled as an alarm source and motion isdetected, an alarm condition will be declared.(In order to use motion detection as an alarm source, motiondetection must be enabled. See Section 3.5 on page 34 for moreinformation about motion detection.)If the user trigger is enabled as an alarm source, youcan click the User Trigger button to declare an alarmcondition.User Trigger