Baumer_GIM500R_Analog_MA_EN.docx 13/20 Baumer IVO GmbH & Co. KG11.04.18 Villingen-Schwenningen, Germany3.4 2-point teaching operationThe 2-point teaching operation is only supported by 1-dimensional inclination sensors with measuring range0... 360°.2-point teaching means the measuring range is defined manually by teaching the minimum and maximumvalues. Within the sensing range, the output signals come as analog values. Outside the sensing range, theoutput value jumps from the maximum to the minimum signal value at half the rotation angle (see 3.3.1Analog output signals). When the sensor is inclined in the opposite direction the value jumps from theminimum to the maximum signal value.To activate the teaching function, apply a HIGH signal (≥ 0.7 * Vs) at pin 5 of the teach input (see 4.1Electrical connection). The two limits must not be too close to each other but provide a minimum angulardifference of > 5°.(see 4.1Electrical connection).3.4.1 The teaching operationAction LED DescriptionInitial situation DUO-LED is green continuousActivate> 5 sStart the teaching operation within 5 minutes afterpower on. Set teach input on HIGH for >5 seconds(≥ 0.7 * +Vs).DUO-LED: flashing amber after 5 secondsGet sensor to position 1 Get inclination sensor into the position intended formin. voltage output / current outputConfirm position 1> 0.1 sSet teach input on HIGH for >0.1 sec.DUO-LED: Amber continuous for 3 seconds, thenflashingGet sensor to position 2 Get sensor to the position for maximum voltage/currentoutput. Make sure there is a difference of >5° betweenthe two positions.Sens of rotation in the teaching operation is the sameas in the later application.Confirm position 2> 0.1 sSet teach input on HIGH for >0.1 sec.DUO-LED: amber continuous for 3 seconds, followedby 3x flashing green.Teach inputUTeach inputUTeach inputU