175 Installation5.8 Connecting the Compressed Air! Attention!Adjustments and function control were done with a compressed air value of 4.5 bar.The applicator operating range is between 4.0 and 6.0 bar.! Warning!When connecting the applicator to compressed air it is considered "IN USE!" Cylinder motion is possible! Do not reach into the zone of the moving pad and keep long hair, loose clothes, and jewelry away.21341 Check that the stop valve (2) is closed asillustrated2 Attach compressed air to connector (1).3 Open the stop valve (2) by turning it into thedirection of air flow.4 Switch on the printer by the power switch.It is possible to use an air pressure regulation unit.cab offers two versions of air pressure regulators.• Air pressure regulation unit with includedmagnetic valve (3)Controlling via printer Interface description of the printer• Standard air pressure regulation unit (4)Fig. 13 Compressed air connectioni Note!If the pad is not in the start position when the printer is switched on an error message appears on thedisplay.Press the pause button on the printer.The applicator will move into the start position and will be ready for use.i Note!Only mount the air pressure regulation unit as illustrated otherwise the functionality of the air-waterseparator cannot be guaranteed.