SECTION 4. SENSOR INSTALLATION4-34.5 03001 RM YOUNG WIND SENTRYWIND SETThe 03001 can be mounted directly to the mast,or to the 019ALU Crossarm.4.5.1 03001 MOUNTED TO THE MASTMount the 03001 to the mast as shown inFigure 4.5-1.1. Slide the crossarm mounting bracket ontothe mast. Orient the crossarm so the vaneend points north, and tighten the bandclamp (see Section 4.19 for finalcalibration).2. Attach the cup assembly to theanemometer shaft using the allen wrenchprovided.4.5.2 03001 MOUNTED TO 019ALU CROSSARMMount the 03001 to the 019ALU crossarm asshown in Figure 4.5-2.1. Position the top of the mounting post 5"above the 3/4" NU-RAIL and tighten the setscrews.2. Slide the crossarm mounting bracket ontothe mounting post. Orient the crossarm sothe vane end points north, and tighten theband clamp (see Section 4.19 for finalcalibration).3. Attach the cup assembly to theanemometer shaft using the allen wrenchprovided.FIGURE 4.5-1. 03001 Mounted to the MastFIGURE 4.5-2. 03001 Mounted to019ALU Crossarm4.6 03101 RM YOUNG WIND SENTRYANEMOMETERMount the 03101 to the 019ALU crossarm asshown in Figure 4.6-1.1. Screw the mounting post into the mountingbracket on the sensor.2. Position the top of the mounting post 5" abovethe 3/4" NU-RAIL and tighten the set screws.3. Attach the cup assembly to the anemometershaft using the allen wrench provided.FIGURE 4.6-1. 03101 RM Young WindSentry Anemometer0300103001Mounting Post03101Mounting PostNU-RAIL019ALU