SECTION 4. SENSOR INSTALLATION4-44.7 LICOR SILICON RADIATIONSENSORS (LI200X, LI200S, LI190SB)Mount the Radiation Sensor to the LI2003S Baseand Leveling Fixture as shown in Figure 4.7-1.1. Position the base of the sensor in themounting flange on the LI2003S, andtighten the set screw with the allen wrenchprovided. Adjust the three leveling screwsflush with the bottom of the LI2003S.2. Mount the LI2003S to the 025 or 015(Section 2.2) using the three mountingscrews provided. Do not tighten the screwsat this time.3. Level the LI2003S using the bubble leveland leveling screws and tighten themounting screws. Remove the redprotective cap prior to use.FIGURE 4.7-1. LI200X/LI200S/LI190SB andLI2003S Leveling Fixture4.8 107/108 TEMPERATURE PROBEMount the 107 temperature probe inside the41301 (UT6P) 6-Plate Gill Radiation Shield asshown in Figure 4.8-1.1. Loosen the two mounting clamp screws onthe base of the 41301 (UT6P). Insert the107 probe through the mounting clamp untilthe white heat shrink is even with thebottom of the clamp.2. Tighten the two screws evenly until theclamp is snug against the sensor lead.FIGURE 4.8-1. 107 Temperature ProbeBullseyelevel(3) LevelingScrews(3) MountingScrewsSensor015 or 025Mounting BaseMounting Clamp107UT018Mounting Clamp10741301UT6P