ZR70 MC A, ZR65 MC A, ZR60 ACHAPTER 3. INFORMATION FOR REPAIR · SERVICE HINTS3-104-3 Cleaning ModeWhen cleaning the head with hard-type cleaning tape (DY9-1384-000), set up the cleaning mode according to the procedure givenbelow.Note : After head cleaning, be sure to restore the settings to normal.4-4 Commands Particular to Camera(1) The commands particular to camera are provided for checking the operation.(2) Make preparation according to the table below and carry out the desired commands particular to camera.(3) To restore any setting back to the original status, press the PAUSE key (STORE) for each item again in the “ST” mode.Turning the power OFF/ON resets all the settings.ST EP PROCEDURE MONIT OR Microcomputer operationCS Function ADDR MODE DT1 1) Make setting shown at right. 0 10 0111 ST --2) Increases DT by 2. ↑ ↑ ↑ ↑ --(Change bit-02 to 1 from 0.)(Example: 80 → 82)3) Perform ST ORE. (Press PAUSE key. ↑ ↑ ↑ RD -- Completion of cleaning mode setup2 1) Change over to the normal mode and turn OFF the power supply. Resetting of cleaning modeST EP PROCEDURE Microcomputer operationCAM SPECIAL COMMAND CS Function ADDR MODE DTWB SET 1) Make setting shown at right. 2 08 3300 ST --2) Execute ST ORE. (Press PAUSE.) ↑ ↑ ↑ RD -- WB is set.WB 1) Make setting shown at right. 2 08 3301 ST --LOCK 2) Execute ST ORE. (Press PAUSE.) ↑ ↑ ↑ RD -- WB is locked.WB 1) Make setting shown at right. 2 08 3302 ST --T URBO 2) Execute ST ORE. (Press PAUSE.) ↑ ↑ ↑ RD -- WB high-speed setting modeWB 1) Make setting shown at right. 2 08 3303 ST --OUT DOOR 2) Execute ST ORE. (Press PAUSE.) ↑ ↑ ↑ RD -- WB outdoor modeWB 1) Make setting shown at right. 2 08 3304 ST --INDOOR 2) Execute ST ORE. (Press PAUSE.) ↑ ↑ ↑ RD -- WB indoor modeIRIS 1) Make setting shown at right. 2 08 3305 ST --OPEN 2) Execute ST ORE. (Press PAUSE.) ↑ ↑ ↑ RD -- T he iris is opened forcibly.IRIS 1) Make setting shown at right. 2 08 3306 ST --CLOSE 2) Execute ST ORE. (Press PAUSE.) ↑ ↑ ↑ RD -- T he iris is closed forcibly.AGC 1) Make setting shown at right. 2 08 3307 ST --MAX 2) Execute ST ORE. (Press PAUSE.) ↑ ↑ ↑ RD -- A value of AGC gain is maximized.AGC 1) Make setting shown at right. 2 08 3308 ST --MIN 2) Execute ST ORE. (Press PAUSE.) ↑ ↑ ↑ RD -- A value of AGC gain is minimized.COLOR 1) Make setting shown at right. 2 08 3309 ST --BAR 2) Execute ST ORE. (Press PAUSE.) ↑ ↑ ↑ RD -- Outputs color bar from MACS.White 1) Make setting shown at right. 2 08 330A ST --100% 2) Execute ST ORE. (Press PAUSE.) ↑ ↑ ↑ RD -- Outputs white 100% from MACS.White 1) Make setting shown at right. 2 08 330B ST --50% 2) Execute ST ORE. (Press PAUSE.) ↑ ↑ ↑ RD -- Outputs white 50% from MACS.MONIT OR