0004 While output is being generated,the AD value of the transferoutput current is 205 (DEC) ormore for 100 msec 2 times insequence. (However, afteroutput, it is not detected for 100msec.)Replace the high-voltage powersupply. Replace the controllerPCB.0005 While output is being generated,the AD value of the transferoutput voltage is 0 (DEC) for100 msec 2 times in sequence.(However, after output, it is notdetected for 100 msec.)Replace the high-voltage powersupply. Replace the DC controllerPCB.E100 The BD interval is outside a specific range.0001 After the machine has becomeready for image formation (i.e.,the scanner motor is ready foroperation, and the laser has beenturned on), an error has occurred50 times or more (BD error).Replace the laser unit. Replace theDC controller PCB. Check thewiring.E110 The scanner motor is faulty.0001 The scanner motor speed locksignal does not indicate a lockedstate a specific period of timeafter the scanner motor has beenstarted.Replace the laser unit. Replace theDC controller PCB. Check thewiring.0002 The speed lock signal indicates adeviation 10 times in sequence atintervals of 10 msec after thesignal has indicated a lockedstate.Replace the laser unit. Replace theDC controller PCB. Check thewiring.0003 With the image clock switchedover, the scanner motor speedlock signal does not indicate alocked state 6.5 sec after aswitchover is made from low tonormal speed or 8 sec after aswitchover is made from normalto low speed.Replace the laser unit. Replace theDC controller PCB. Check thewiring.Code Cause Remedy