COPYRIGHT © 2001 CANON INC. 2000 2000 2000 2000 CANON iR8500 REV.0 MAR. 2001 4-1CHAPTER 4 INSTALLATION1 Selecting the SiteSelect the site of installation, making sure it meets the following requirements; if possible,visit the site before delivery of the machine:1. The site must provide an electrical outlet rated as indicated and available for exclusiveuse by the machine.2. The site’s ambient temperature must be between 15° and 30°C and the humidity, be-tween 5% and 80%. Avoid areas near a water faucet, water boiler, humidifier, and refrig-erator.3. The site must not be near a source of fire or subject to dust or ammonium gas. Avoid ar-eas exposed to the direct rays of the sun; otherwise, provide curtains.4. The site must be well ventilated. The level of ozone generated by the machine in opera-tion should not affect the health of the individuals around it. However, some may find itsodor unpleasant as when the room is poorly ventilated.5. The site’s floor must ensure that the machine’s feet will remain in contact, and the ma-chine will remain level.6. Install the machine so that it is at least 10 cm away from any wall, and there is adequatespace for using the machine.