CarNetix PSU-PC19 V2.0 Installation Manual2.2.1 Setting JP1 JumpersBelow is a table with the jumper selectable options that appear on JP1. To move a jumper from itsfactory default position (open), use a pair of tweezers or needle nose pliers. Be careful to place thejumper in the correct position or erratic behavior could result. Double-check your settings beforereplacing the lid.Pins1-2 3-4 5-6 7-8 9-10Function Pulse StartInputDeadmanTimerHibernate/Standby Not Used ShutdownDelay TimeOpen(default)Connect toexternalcontactclosureDeadmanTimerDisabledHibernate Not Used 6 SecondsJumperedConnect toexternalcontactclosureDeadmanTimerEnabledStandby Not Used 15 minutes- 10 -