9015. Electrical DataSplitSystemModelStartingCurrent(Note 1)SystemPowerSupplyElectrical ConsumptionCircuitBreakerCooling Heating*****35 °C*43 °C**46 °C***52 °C****Heat Pump Amp V/Ph/Hz Amp Watt Amp Watt Amp Watt Amp Watt Amp Watt Amp53QDMT12-718 35 220-240 5.9 1265 6.5 1330 6.8 1355 7.3 1400 5.1 1045 1653QDMT18-718 58 220-240 9.2 1985 10.4 2095 10.9 2135 11.9 2215 7.8 1695 2053QDMT24-718 72 220-240 11.2 2415 12.4 2540 12.9 2585 13.8 2675 10.2 2125 2553QDMT30-718 91 220-240 16.3 3515 18.5 3690 19.4 3760 21.1 3900 12.3 2755 3253QDMT36-718 115 220-240 20.9 4195 23.7 4400 24.7 4490 26.7 4670 16.8 3220 4053QDMT36-518 61 380-420 7.2 4105 8.3 4315 8.6 4405 9.3 4580 5.9 3200 2053QDMT42-718 115 220-240 22.5 4555 25.3 4785 26.4 4870 28.4 5040 16.9 3200 4053QDMT42-518 61 380-420 7.2 4245 8.3 4460 8.6 4540 9.3 4695 5.4 2975 2053QDMT48-518 61 380-420 7.5 4200 8.6 4415 9.0 4490 9.7 4645 6.7 3795 2053QDMT60-518 77 380-420 8.3 4725 9.4 4960 9.8 5050 10.6 5230 7.6 4155 20NOTES1. Starting Current duration is usually less than 1 Second.2. Operating Conditions.* @ 35ºC db outdoor temperature :27/19ºC db/wb Indoor Temperature. High air flow of indoor unit** @ 43ºC db outdoor temperature :27/19ºC db/wb Indoor Temperature. High air flow of indoor unit*** @ 46ºC db outdoor temperature :29/19ºC db/wb Indoor Temperature. High air flow of indoor unit**** @ 52ºC db outdoor temperature :32/23ºC db/wb Indoor Temperature. High air flow of indoor unit***** Standard operating conditions for heatingIndoor 20 °C DBT Outdoor 7/6 °C DBT/WBT High air flow of indoor unit