3Physical data* Tube sizes are for runs up to 50 ft. For tube set over 50 ft horizontal or 20 ft vertical differential, consult Residential Split Systems Long-Line Appli-cation Guideline.NOTE: See unit Installation Instructions for proper installation.METERING DEVICEUNIT SIZE 018 024 030 036 042 048 060OPERATING WT (Lb) 115 166 188 208 209 250 278COMPRESSORType ScrollREFRIGERANT R-22Control PistonCharge (Lb)@15 Ft 5.5 5.63 7.88 9.88 10.63 11.13 14.0CONDENSER FAN Propeller Type, Direct DriveAir Discharge VerticalAir Qty (CFM) 1700 3000 3300Motor HP 1/12 1/8 1/4Motor RPM (60 Hz) 1100 825 1125CONDENSER COILFace Area (Sq Ft) 12.4 14.93 22.40 16.18 18.67 22.40Fins per In. 20 20 20 20 20Rows 1 1 2 2 2Circuits 2 3 4 5 6VALVE CONNECTION (In. ID) SweatVapor 5/8 3/4 7/8Liquid 3/8REFRIGERANT TUBES*(In. OD)Vapor 5/8 3/4 7/8 1-1/8Liquid 3/8UNITSIZE SERIES OUTDOORPISTON INDOORPISTON018 33, 34 42 52024 33, 34 49 59030 33, 34 55 63036 33, 34 63 78042 33, 34 65 78048 33, 34 73 90060 33, 34 78 101MANUFACTURERCERTIFIEDTOARIASCOMPLYINGWITHARISTA NDARD240UNITARYHEATPUMPEQU IPMENT®CERTIFICATION APPLIES ONLYWHEN THE COMPLETE SYSTEMIS LISTED WITH ARI.REGISTERED QUALITY SYSTEM