HEATING CAPACITIES (cont)50ZH036Temp (F)Air EntIndoorCoil(edb)IndoorAir CFM(Std)Temperature Air Entering Outdoor Coil (F db at 70% rh)−10 0 10 17 20 30 40 47 50 60601050 Cap. 11.4 10.5 14.4 13.2 17.6 16.2 20.1 18.3 21.2 19.2 25.3 22.2 30.1 30.1 34.0 34.0 35.4 35.4 41.9 41.9kW 2.48 2.56 2.65 2.71 2.74 2.85 2.98 3.09 3.12 3.311200 Cap. 11.6 10.7 14.6 13.4 17.9 16.4 20.3 18.5 21.4 19.4 25.6 22.4 30.4 30.4 34.3 34.3 35.8 35.8 42.2 42.2kW 2.51 2.58 2.66 2.71 2.74 2.84 2.95 3.05 3.08 3.241350 Cap. 11.8 10.9 14.8 13.6 18.1 16.6 20.5 18.7 21.6 19.6 25.8 22.6 30.6 30.6 34.6 34.6 36.0 36.0 42.4 42.4kW 2.55 2.61 2.68 2.73 2.75 2.84 2.94 3.03 3.06 3.19701050 Cap. 10.8 9.96 13.9 12.8 17.3 15.8 19.8 18.1 20.9 19.0 25.0 21.9 29.7 29.7 33.5 33.5 34.9 34.9 41.2 41.2kW 2.66 2.76 2.86 2.94 2.97 3.09 3.23 3.35 3.39 3.591200 Cap. 11.1 10.2 14.1 13.0 17.5 16.1 20.0 18.2 21.1 19.2 25.2 22.1 29.9 29.9 33.8 33.8 35.2 35.2 41.7 41.7kW 2.69 2.78 2.87 2.93 2.96 3.07 3.19 3.30 3.34 3.521350 Cap. 11.3 10.4 14.3 13.2 17.7 16.2 20.2 18.4 21.3 19.4 25.4 22.3 30.2 30.2 34.1 34.1 35.5 35.5 42.0 42.0kW 2.73 2.81 2.89 2.94 2.97 3.07 3.18 3.27 3.31 3.47801050 Cap. 10.1 9.29 13.3 12.3 16.8 15.5 19.5 17.8 20.7 18.8 24.9 21.8 29.4 29.4 33.4 33.4 34.7 34.7 40.8 40.8kW 2.84 2.97 3.10 3.19 3.23 3.37 3.53 3.67 3.71 3.911200 Cap. 10.3 9.52 13.6 12.5 17.1 15.7 19.8 18.0 21.0 19.1 25.2 22.0 29.7 29.7 33.8 33.8 35.1 35.1 41.3 41.3kW 2.87 2.99 3.10 3.18 3.22 3.35 3.48 3.61 3.64 3.821350 Cap. 10.6 9.72 13.8 12.7 17.3 15.9 20.0 18.2 21.3 19.3 25.4 22.3 29.9 29.9 34.1 34.1 35.4 35.4 41.5 41.5kW 2.91 3.02 3.12 3.19 3.22 3.34 3.46 3.57 3.61 3.75LEGENDCap. — Heating Capacity (1000 Btuh) (Includes Indoor-Fan Motor Heat)db — Dry BulbkW — Total Power Input (Includes Compressor Motor Power Input, Outdoor-Fan Motor Input, and Indoor-Fan Motor Input)rh — Relative HumidityNOTES:1. indicates integrated ratings.2. Integrated capacity is maximum (instantaneous) capacity less the effect of froston the outdoor coil and the heat required to defrost it.50ZH042Temp (F)Air EntIndoorCoil(edb)IndoorAir CFM(Std)Temperature Air Entering Outdoor Coil (F db at 70% rh)−10 0 10 17 20 30 40 47 50 60601225 Cap. 13.4 12.4 16.9 15.5 20.7 19.0 23.7 21.6 25.2 22.9 29.8 26.1 35.2 35.2 40.3 40.3 42.4 42.4 49.7 49.7kW 2.87 2.98 3.09 3.17 3.22 3.35 3.51 3.66 3.73 3.971400 Cap. 13.4 12.3 16.8 15.4 20.9 19.2 23.9 21.8 25.3 23.0 30.2 26.5 35.6 35.6 40.8 40.8 42.7 42.7 50.4 50.4kW 2.90 3.00 3.10 3.18 3.22 3.34 3.48 3.62 3.67 3.901575 Cap. 13.3 12.3 17.0 15.6 21.1 19.4 24.2 22.1 25.6 23.2 30.5 26.8 36.0 36.0 41.2 41.2 43.0 43.0 50.9 50.9kW 2.95 3.04 3.13 3.20 3.23 3.35 3.48 3.61 3.65 3.86701225 Cap. 12.5 11.5 16.1 14.8 20.0 18.3 23.1 21.1 24.6 22.4 29.2 25.6 34.5 34.5 39.5 39.5 41.6 41.6 48.7 48.7kW 3.06 3.19 3.32 3.43 3.47 3.63 3.80 3.97 4.04 4.301400 Cap. 12.5 11.5 16.0 14.7 20.2 18.5 23.4 21.3 24.8 22.5 29.6 25.9 34.9 34.9 40.0 40.0 41.8 41.8 49.3 49.3kW 3.09 3.21 3.34 3.43 3.47 3.61 3.76 3.92 3.97 4.211575 Cap. 12.4 11.4 16.2 14.9 20.5 18.8 23.7 21.6 25.1 22.7 29.9 26.2 35.3 35.3 40.4 40.4 42.2 42.2 49.9 49.9kW 3.14 3.25 3.36 3.45 3.48 3.61 3.75 3.89 3.94 4.16801225 Cap. 11.4 10.5 15.1 13.9 19.1 17.5 22.4 20.4 24.0 21.7 28.6 25.1 33.8 33.8 38.7 38.7 40.8 40.8 47.7 47.7kW 3.25 3.41 3.57 3.69 3.75 3.93 4.13 4.31 4.38 4.661400 Cap. 11.4 10.5 15.0 13.8 19.3 17.8 22.7 20.7 24.2 21.9 29.0 25.4 34.2 34.2 39.2 39.2 41.0 41.0 48.3 48.3kW 3.29 3.44 3.59 3.70 3.74 3.91 4.08 4.25 4.30 4.561575 Cap. 11.4 10.4 15.2 14.0 19.7 18.0 23.0 21.0 24.5 22.2 29.3 25.7 34.6 34.6 39.6 39.6 41.4 41.4 48.9 48.9kW 3.33 3.47 3.61 3.71 3.75 3.90 4.06 4.21 4.26 4.50LEGENDCap. — Heating Capacity (1000 Btuh) (Includes Indoor-Fan Motor Heat)db — Dry BulbkW — Total Power Input (Includes Compressor Motor Power Input, Outdoor-Fan Motor Input, and Indoor-Fan Motor Input)rh — Relative HumidityNOTES:1. indicates integrated ratings.2. Integrated capacity is maximum (instantaneous) capacity less the effect of froston the outdoor coil and the heat required to defrost it.13