T-354 3–43.1.5 Air-cooled Condenser SectionThe air-cooled condenser section (Figure 3.4) consists of the condenser fan, condenser coil, receiver with sightglass/moisture indicator, quench valve, manual liquid line valve, filter-drier, condenser pressure transducer, andfusible plug.The condenser fan pulls air in through the bottom of the coil and discharges it horizontally out through the con-denser fan grille.Figure 3.4 Air-cooled Condenser Section1. Grille and Venturi Assembly2. Condenser Fan3. Key4. Condenser Fan Motor5. Condenser Coil Cover6. Condenser Coil7. Condenser Motor Mounting Bracket8. Receiver9. Sight Glass10. Fusible Plug (Rupture Disc - Alternate)11. Condenser Pressure Transducer12. Sight Glass/Moisture Indicator13. Filter-Drier14. Liquid Line Service Valve15. Quench Valve- - - - -213 456789101112131415