T-354 5–45.6 STARTING AND STOPPING INSTRUCTIONSWARNING!Make sure that the unit circuit breaker(s) (CB-1 & CB-2) and the START-STOP switch (ST) are inthe “O” (OFF) position before connecting to any electrical power source.5.6.1 Starting the Unit1. With power properly applied, the fresh air damper set, and if required, the water-cooled condenser con-nected (refer to sections 5.2, 5.3, and 5.4), place the START-STOP switch to “I” (ON).2. Continue with Start Up Inspection (refer to Section 5.7).5.6.2 Stopping the UnitTo stop the unit, place the START-STOP switch in position “O” (OFF).5.7 START-UP INSPECTION5.7.1 Physical Inspection1. Check rotation of condenser and evaporator fans.2. Check compressor oil level (refer to Section 7.8.6).5.7.2 Check Controller Function CodesCheck and, if required, reset controller Function Codes (Cd27 through Cd39) in accordance with desired operatingparameters (refer to Section 4.2.2).5.7.3 Start Temperature Recorder1. Open recorder door and wind mechanical clock or check battery of electronic recorder. Be sure key isreturned to storage clip of mechanical recorder.2. Lift stylus (pen) by pulling the marking tip outward until the stylus arm snaps into its retracted position.3. Install new chart making sure chart is under the four corner tabs. Lower the stylus until it has made contactwith the chart. Close and secure door.5.7.4 DataCORDER1. Check, and if required, set the DataCORDER Configuration in accordance with desired recording parameter(refer to Section 4.6.3).2. Enter a “Trip Start”. To enter a “Trip Start”, do the following:a. Depress the ALT MODE key and scroll to Code dC30.b. Depress and hold the ENTER key for five seconds.c. The “Trip Start” event will be entered in the DataCORDER.5.7.5 Complete InspectionAllow unit to run for five minutes to stabilize conditions and perform a pre-trip diagnosis in accordance with the fol-lowing paragraph.