450PCH015-060 UNITSNOTES:1. While clear access to all removable panels is not required, installer shouldtake care to comply with all building codes and allow adequate clearancefor future field service.2. Horizontal units shipped with filter bracket only. This bracket should beremoved for return duct connection.3. Discharge flange and hanger brackets are factory installed.4. Condensate is 3/4-in. (19.1 mm) IPT copper.5. Blower service panel requires 2 ft (610 mm) service access.6. Blower service access is through back panel on straight (right or left) dis-charge units or through panel opposite air coil on back discharge units.50PCHUNITSIZEOVERALL CABINET WATERCONNECTIONS ELECTRICAL KNOCKOUTS DISCHARGE CONNECTIONSDUCT FLANGE(± 0.10 in., ± 2.5 mm)RETURN CONNECTIONUSING RETURN AIROPENINGAWidth BDepth CHeight1 2 3 4Size(IPT)H1/2-in.J1/ 2-in.K3/4-in. LMSupplyHeightNSupplyWidthO PQReturnDepthRReturnHeightS TLoop In Loop OutD E F G LowVoltageLowVoltagePowerSupply015 in. 20.1 43.1 17.0 15.1 1.4 3.2 1.4 1/ 2 12.1 9.1 6.1 2.6 13.3 9.9 4.1 1.3 23.0 15.0 1.1 1.0cm 51.1 109.5 43.2 38.4 3.4 8.1 3.5 1.3 30.8 23.2 15.6 6.6 33.8 25.1 10.5 3.3 58.4 38.1 2.8 2.5018 in. 20.1 43.1 17.0 15.1 1.4 4.1 1.4 1/ 2 12.1 9.1 6.1 2.6 13.3 9.9 4.1 1.3 23.0 15.0 1.1 1.0cm 51.1 109.5 43.2 38.4 3.4 10.4 3.5 1.3 30.8 23.2 15.6 6.6 33.8 25.1 10.5 3.3 58.4 38.1 2.8 2.5024 in. 20.1 43.1 18.3 15.1 1.4 4.4 1.4 3/ 4 12.1 9.1 6.1 2.6 13.3 9.9 4.1 1.3 23.0 16.3 1.1 1.0cm 51.1 109.5 46.5 38.4 3.4 11.3 3.5 1.9 30.8 23.2 15.6 6.6 33.8 25.1 10.5 3.3 58.4 41.4 2.8 2.5030 in. 20.1 43.1 18.3 15.1 1.4 3.1 1.4 3/ 4 12.1 9.1 6.1 2.6 13.3 9.9 4.1 1.3 23.0 16.3 1.1 1.0cm 51.1 109.5 46.5 38.4 3.4 7.8 3.5 1.9 30.8 23.2 15.6 6.6 33.8 25.1 10.5 3.3 58.4 41.4 2.8 2.5036 in. 20.1 47.1 21.0 15.1 1.4 5.3 1.4 3/ 4 16.1 13.1 10.1 2.5 16.1 11.0 3.0 2.5 25.9 19.0 1.1 1.0cm 51.1 119.6 53.3 38.4 3.4 13.4 3.5 1.9 41.0 33.3 25.7 6.3 40.9 27.9 7.7 6.4 65.8 48.3 2.8 2.5042 in. 20.1 47.1 21.0 15.1 1.4 4.4 1.4 3/ 4 16.1 13.1 10.1 2.5 16.1 11.0 3.0 2.5 25.9 19.0 1.1 1.0cm 51.1 119.6 53.3 38.4 3.4 11.3 3.5 1.9 41.0 33.3 25.7 6.3 40.9 27.9 7.7 6.4 65.8 48.3 2.8 2.5048 in. 24.1 54.1 21.0 15.1 1.4 4.4 1.4 1 16.1 13.1 10.1 3.7 16.1 13.7 4.1 1.3 35.9 19.0 1.1 1.0cm 61.2 137.4 53.3 38.4 3.4 11.1 3.5 2.5 41.0 33.3 25.7 9.5 41.0 34.8 10.3 3.2 91.2 48.3 2.8 2.5060 in. 24.1 54.1 21.0 15.1 1.4 3.8 1.4 1 16.1 13.1 10.1 1.7 18.1 13.7 4.1 1.3 35.9 19.0 1.1 1.0cm 61.2 137.4 53.3 38.4 3.4 9.7 3.5 2.5 41.0 33.3 25.7 4.4 46.0 34.8 10.3 3.2 91.2 48.3 2.8 2.5AIRFLOW CONFIGURATIONCode Return DischargeD or S Left RightE or F Left BackA or Z Right LeftB or C Right BackFig. 1 — 50PCH Unit DimensionsFRIGHT RETURN STRAIGHT DISCHARGEFRONTL NOMRIGHT RETURNFRONTSTRAIGHTDISCHARGECSPBACKDISCHARGECONDENSATE3 / 4" IPT3.3"[83.8 MM]0.7"[17.8 MM]FRONT-VIEWE DK J 211.1 [27.9 MM]ACAPBSPRIGHT RETURN RIGHT VIEW -AIR COIL OPENINGAIR COILCTSBRQFRONTLN OMLEFT RETURN STRAIGHT DISCHARGEFRONTBSPLEFT RETURN RIGHT RETURNAIR COILCSPFRONTLEFT RETURN LEFT VIEW -AIR COIL OPENING1.75 [44.5 MM]CTRQSBUNIT HANGER DETAILUVFRONTWMODEL U V W015-030 43.1 [109.5] 22.2 [56.4] 18.0 [45.7]036-042 47.1 [119.6] 22.2 [56.4] 18.0 [45.7]048-060 54.1 [137.4] 26.2 [66.5] 22.0 [55.9]RIGHT RETURN BACK DISCHARGEAAIR COIL SIDECPNOMCSPBSP2 FT [610 MM] SERVICEACCESSFRONTLEFT RETURN0.7" [17.8 MM]3.3"[83.8 MM]CSPCONDENSATE3 / 4" IPT2 FT [610 MM] SERVICEACCESSAIR COIL SIDEMACLEFT RETURN BACK DISCHARGENOPBSPBLOWEROUTLETBLOWEROUTLETBLOWEROUTLETBLOWEROUTLETOPTIONAL 2 FT[610 MM]SERVICEACCESSOPTIONAL 2 FT[610 MM]SERVICEACCESSGHNOTE: BLOWER SERVICE PANEL REQUIRES 2 FT SERVICE ACCESSPOWER SUPPLY3 / 4" [19.1 MM] KNOCKOUT1 / 2"[12.7 MM]KNOCKOUTLOW VOLTAGE1 / 2" [12.7 MM]KNOCKOUT3STRAIGHTDISCHARGEBACKDISCHARGENOTE: CHOOSE EITHERBACK OR STRAIGHT DISCHARGE NOTE: CHOOSE EITHERBACK OR STRAIGHT DISCHARGELEGENDBSP — Blower Service PanelCAP — Control Access PanelCSP — Compressor Service PanelIPT — Internal Pipe Threada50-8412