39Table 3 — ICVC Display Data (cont)EXAMPLE 18 — OPTIONS DISPLAY SCREENTo access this display from the ICVC default screen:1. Press .2. Press .3. Scroll down to highlight .4. Press .5. Scroll down to highlight .6. Press .NOTE: No variables are available for CCN read or write operation.EXAMPLE 19 — VDO_SRD DISPLAY SCREENTo access this display from the ICVC default screen:1. Press .2. Press .3. Scroll down to highlight .4. Press .5. Scroll down to highlight .6. Press .NOTE: No variables are available for CCN read or write operation.DESCRIPTION STATUS UNITS POINT DEFAULTAuto Restart Option 0/1 DSABLE/ENABLE ASTART DSABLEGuide Vane Closure 4-25 % GV_CLOSE 4Remote Contacts Option 0/1 DSABLE/ENABLE MODES DSABLESoft Stop Amps Threshold 40-100 % STRTSTOP 100Surge / Hot Gas BypassSurge Limit/HGBP Option 0, 1, 2 srg_hgbp 0Select: Surge=0, HGBP=1Low Load HGBP=2Minimum Load PointSurge/HGBP Delta Tsmin 0.0-150.0 ^ F DTsatmin 45Surge/HGBP IGVmin 0.0-110.0 % GV_MIN 5.0Full Load PointSurge/HGBP Delta Tsmax 0.0-150.0 ^ F DTsatmax 70Surge/HGBP IGVmax 0.0-110.0 % GV_MAX 5.0Surge Line Shape Factor -1.000 - 0.000 shapefac -0.040Surge Line Speed Factor 0.00-3.00 VFD_POW 1.85Surge Line High Offset 0.1-3.0 SP_HIGH 1.0Surge/HGBP Deadband 0.5-3 ^ F hgb_db 1HGBP On Delta T 0.5-10.0 ^ F Hgb_ton 2.0HGBP Off Delta T 0.5-10.0 ^ F Hgb_toff 4.0Surge ProtectionSurge Delta % Amps 5-40 % surge_a 20Surge Time Period 7-10 MIN surge_t 8Surge Delay Time 0-120 SEC SURG_DEL 0Ice Build ControlIce Build Option 0/1 DSABLE/ENABLE Ibopt DSABLEIce Build Termination 0-2 Ibterm 00=Temp, 1=Contact, 2=BothIce Build Recycle 0/1 DSABLE/ENABLE Ibrecyc DSABLERefrigerant Leak Option 0/1 DSABLE/ENABLE LEAK_EN DSABLERefrigerant Leak Alarm mA 4-20 MA LEAK_MA 20Head Pressure ReferenceDelta P at 0% (4 Ma) 20-85 PSI HPDP0 25Delta P at 100% (20 mA) 20-85 PSI HPDP100 50Minimum Output 0-100 % HPDPMIN% 0DESCRIPTION STATUS UNITS POINT DEFAULTDiffuser ControlDiffuser Option 0/1 DIFF_OPT 0Diffuser Full Span mA 15-22 mA DIFF_MA 18.0Guide Vane 25% Load (2) 0-83 % GV1_25 6.4Guide Vane 50% Load (2) 0-83 % GV1_50 22.9Guide Vane 75% Load (2) 0-83 % GV1_75 41.3SRD 25% Load (1) 0-100 % SRD1_25 73.5SRD 50% Load (1) 0-100 % SRD1_50 35.1SRD 75% Load (1) 0-100 % SRD1_75 19.5Lift @ 25% Load (1) 0-100 ^F LF1_25 52.4Lift @ 100% Load (1) 0-100 ^F LF1_100 67.5Lift @ 25% Load (2) 0-100 ^F LF2_25 27.2SRD IGV Offset Select 1-5 OFF_SEL 3Low Lift Profile Select 1-5 PRO_SEL 3MENUSERVICEEQUIPMENT SERVICESELECTOPTIONSSELECTMENUSERVICEEQUIPMENT SERVICESELECTVDO_SRDSELECT