- 26 -3. In-line connection1) System connection diagramThe maximum In-line (ARCNET) cable length and maximum connection unit will bevaried by the In-line communication speed as shown below:NOTE: The terminater 100 ohms is necessary to mount at the end of In-line cable .In line communication speed Maximum Maximum(Baud rate) connection unit cable length A ( m )312.5 K bps 20 units 430 m156.25 K bps 32 units 890 mTerminater (100 ohms) Terminater (100 ohms)2) In-line cable and connectorCASIO TECHNO will supply the In-line cable, connector and terminater parts by thefollowing parts code.In line cableCode No. Parts name Specification1904 4023 In-line cable IPEV-SLA0.5x1PIn line connectorCode No. Parts name Specification3500 5820 In-line connector kit XLP-KIT-1TerminaterCode No. Parts name Specification2600 2516 Carbon film resistor R-25-100-JSignal PinSD 1RD 2FG FG plate(In-line connector)3) In-line cable connectionIn-line cable connection diagram is shown below:Mount the terminater 100 ohms at the both end of In-line cable.Signal PinSD 1RD 2FG FG plate(In-line connector)Signal PinSD 1RD 2FG FG plate(In-line connector)Terminater100 ohmsTerminater100 ohmsTotal In-line cable length is max. A m.