3-22 DATASONICSVolume I System Manual June 1998Configuring the Display Parameter SettingsThe display parameter settings should be verified or reconfigured inaccordance with the standard and optional sensors installed; however, theycan be changed at any time. When running Chirpscan3 for the first time, thedisplay parameter settings are set to display sidescan sonar data and datafrom all the standard sensors. The displays include Port Sidescan andStarboard Sidescan, Pitch and Roll, Heading and Course, and Altitude.To verify or reconfigure the display setup parameters for all the standardsensors:1. Select File from the menu bar, and then choose Setup. The Setup dialogbox shown in Figure 3-8 on page 3-19 opens.2. Click the SS, Bottom Track, PR, and HC data windows to turn them on.3. In the Setup dialog box Click OK to close the Setup dialog box and savethe settings as the default settings, or click Cancel to close the dialog boxwithout saving the settings as the default settings.4. Select Data Window from the menu bar, and then choose Attitude. TheAttitude dialog box shown in Figure 3-11 opens.5. Select the Pitch & Roll and Heading & Compass check boxes.Figure 3-11 The Attitude Dialog Box