INSTALLATION INSTRUCTIONSGAS CONNECTHON FOR CT-365 GAS CONNECTHON FOR CT-304COUNTERTOP COUNTERTOPRequired when unit is h_stal]ed over Wall OvenPower Requirements:120 VAC, 60 Hz., singHe phase.CT-304/CT-365:0.10 Amp. Max.(Use 15 Amp.circuit minimum)I AHways disconnect the eHectric suppHy cord from the wall] outlier or turn off:he eHectricity at theservice disconnect before servicing this appHhnce.I Observe all]governing codes and ordinances when grounding, in the absence of which,observeNationa] EHectrica] Code ANSI/NFPA No. 70-1990.Recommended Grounding Method:This appliance is factory equipped with a power supply cord with a three-prong grounding plug (withpolarized parallel blades). It must be plugged into a mating grounding-type receptacle, connected toa correctly polarized 120 Volt circuit. If the circuit does not have a grounding type receptacle, it is theresponsibility and obligation of the installer or user to have the existing receptacle changed to aproperly grounded and polarized receptacle in accordance with all applicable local codes andordinances by a qualified electrician. In the absence of local codes and ordinances, the receptaclereplacement shall be in accordance with the National Electrical Code. THE THIRD GROUND PRONGSHOULD NOT, UNDER ANY CIRCUMSTANCES, BE CUT OR REMOVED.The electrical supply must be a120 volt, 60 Hz single phase, 15 AMP circuit.The power receptacle must be a NEMA 5q5R device toaccept the three prong plug supplied with the unit._THIRD GROUND PRONG10