• the electrical consumption in euros of theheating, water heater (DHW) and other electricalappliances (lights, household appliances, etc.).If you have the RADIO TYWATT option on yourinstallation• the program of the current day per zone.Comfort periodse.g. zone 1HeatingHot water productionother• the outside temperatureWith an associated outside sensor• total consumption of your installationIf you have the RADIO TYWATT option on your instal-lationTo reset all meters, press and hold the init. button for 5seconds.Press repeatedlyResetConsumptionPress repeatedlyOpen WindowE.g. With an associated door/window magnetic contactRADIO TYBOXis on standbyRADIO TYBOXis “activated” anddisplays the statusof the installationPress a buttonFrost Protection controlBoilerActivating the RADIO TYBOXWith a door/window magnetic contactIf a door/window magnetic contact is associated,the heating switches to Frost protection mode if thedoor/window is opened.The RF 640 and RF 650 receivers allows you toassociate up to 8 home automation products (door/win-dow magnetic contact, alarm control centre, remotecontrols, etc.) with the RADIO TYBOX.To associate the different products, refer to the RADIOTYBOX installation guide.Activating the RADIO TYBOXThe receiver (RF 640 or RF 650) instantaneously takesinto account all information coming from a homeautomation product (e.g. an open window).To display this information on the RADIO TYBOX, theRADIO TYBOX must be “activated” by pressing abutton.The update can take a few seconds.Home automation featuresWith a TYXAL alarm control unitIf a TYXAL alarm control unit is associated.When you activate the alarm, the heating willautomatically switch to Economy mode until the nextprogram change.When you activate the alarm, the heating willautomatically switch to Economy mode until the nextprogram change.This override can be cancelled on the RADIO TYBOX,by pressing the override button or by turning theselector knob.With a TYXIA TransmitterWith an associated TYXIA transmitter:- pressing the button once switches the heatingto Comfort mode until the next program change.- pressing the button once switches the heatingto Economy mode until the next program change.The command can be cancelled:- on the TYXIA transmitter, by pressing ,- on the RADIO TYBOX, by pressing the overridebutton or by turning the selector knob.E.g. With an associated remote controlWith a TYDOM 200 remote controlFrom the home domain , pressing the tactilebutton switches off the heating.This off command is cancelled by pressing .Pressing the tactile or button once switches theheating to Comfort or Economy mode, until the nextprogram change.The command can be cancelled:- on the TYDOM 200 remote control, by pressing thetactile button,- on the RADIO TYBOX, by pressing the overridebutton or by turning the selector knob.With a TYDOM telephone transmitterBy calling the TYDOM telephone transmitter, let thesynthesized voice guide you to determine or modify thestatus of the heating system (see the TYDOMtransmitter instructions).Home automation features1 2 34 5 67 8 90 #Separate the thermostatfrom its base.Position the thermostaton its base.Lock the thermostat.Replace the batteries, makingsure they are the right way round.123 4Replacing batteriesWhen the battery level symbol appears, you havearound 1 month to change the batteries(two 1.5 V alkaline batteries, LR03 or AAA).The following precautions must be respected:- Ensure that the +/- polarities are correctly placedwhen the battery is fitted into the unit.- Do not dispose of used batteries in unauthorizedplaces (you should respect the environment by takingthe batteries to a suitable collection site).- Do not recharge the batteries.- You have approximately 30 seconds to change thebatteries before the time is reset to zero(if this happens, reset the date and time).Battery level symbolThe programs cannot be modified and the set-pointtemperature settings are limited (comfort: 16 to 22°C,Economy: 13 to 19°C, Frost Protection: 5 to 11°C).Refer to the installation guide (menu 2-01) or contact your ins-taller or our customer service department.Your heating system is in Frost-Protection mode.The thermostat is in the , , PROGor position.The unit displays: dEF 6.There is a communication fault between the RADIO TYBOXand the RF 640 or RF 650 receivers.Bring the transmitter nearer to the receiver.The indication is displayed.The batteries are low.Change the batteries, making sure they are the right wayround.The device only displays the time and the roomtemperature.RADIO TYBOX is in screen saver display mode, but all theheating features are running.Press a button to "activate" the display.The update can take a few seconds.Nothing is displayed on the room unit screen.There is no power supply.Check the batteries.The unit is in time setting mode.You took too much time in changing the batteries.Set the time. All other settings have remained unchanged.When setting the time, there is no option to set the day.RADIO TYBOX is set to daily programming.To switch to weekly programming, refer to the installation guide(menu 1-01) or contact your installer or our customer servicedepartment.When creating a program, the and symbols do notappear on the screen.Program changes were not authorized during installation.Refer to the installation guide (menu 2-01) or contact your ins-taller or our customer service department.The temperature displayed does not match thetemperature measured in the room (thermometer).Refer to the installation guide (menu 2-02) or contactyour installer or our customer service department.TroubleshootingThe purpose of this section is to help you quickly solvethe most common problems that you may encounterwith your product during use.If you're unsure, or if the problem persists or isn't inthis list, contact our customer service department.During the AUTO, or modes, press the ibutton repeatedly to find out:• the room temperature or the set-pointtemperature (depending on the configurationduring the installation)If your thermostat displays the temperature of the roomInformation buttonSet-point temperature displayReturn to normal display(automatic after about 40 seconds)The display of all information related to homeautomation features (outside temperature, consumptionindication, etc.) requires an “activation” phase from theRADIO TYBOX (see the home automation featuressection). |
Related manuals for DELTA DORE RADIO TYBOX
DELTA DORE TYBOX User Manual
DELTA DORE Rodio Tybox Pac User Manual
DELTA DORE TYBOX PAC User Manual
DELTA DORE Tybox 137 User Manual
DELTA DORE TYBOX 610 User Manual
DELTA DORE TYBOX 117 User Manual
DELTA DORE TYBOX 811 W RF User Manual
DELTA DORE TYBOX 817- 827 W RF User Manual
DELTA DORE Micro TYBOX H RADIO X2D Manual
DELTA DORE TYBOX 23 Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine