Installation (for qualified installers only) 25© Travis Industries 9/25/17-1468 MaestroWiring the Intake DamperWARNING: DO NOT CONNECT THE INTAKE DAMPER WIRES TOGETHER(this will short the system).ROUTE THE WIRES TO THE AIR INTAKE LOCATION EVEN IF DAMPER(S) ARE NOT USEDIntake dampers are strongly recommended in cold areas (see page 33). Even if dampers are notbeing installed, we recommend routing the intake damper wires to the intake location. This allowsdampers to be installed at a later time if desired (to reduce air infiltration, humid glass, etc.). Route the intake damper harness to the air intake location. For external dampers (98900093, 98900094), attachthe quick-connects from the intake damper harnessto the quick connects on the intake damper (seephoto to the right). For internal dampers (98900078, 98900078),remove the quick-connects from the intake damperharness and attach wires directly to the terminalblocks (see photo to the right and page 36 fordetails).