• Monobloc • EDHQ011-016AA6W1• Altherma TM • Monobloc1082 Specifications32Power supplyhydrauliccomponentVoltage range Minimum V -10%Maximum V +10%Wiring connections Connection type for power supply hydraulic compartmentQuantity of wires 4GType of wires Select diameter and type according to national and local regulationsConnection type for power supply connection to optional sanitary tank + Q2LQuantity of wires 3GType of wires Select diameter and type according to national and local regulationsType of wires For more details on voltage range and current refer to installation manualConnection type for connection with R5TQuantity of wires Wire included in option EKHWS*Type of wires Wire included in option EKHWS*Connection type for connection with A3PQuantity of wires Depends on thermostat type, refer to installation manualType of wires Select diameter and type according to national and local regulationsType of wires Voltage 230V / Maximum current: 100mA / Minimum 0.75mm²Connection type for connection with M2SQuantity of wires 3GType of wires Select diameter and type according to national and local regulationsType of wires Voltage 230V / Maximum current: 100mA / Minimum 0.75mm²Connection type for connection with M3SQuantity of wires 3G or 4GType of wires Select diameter and type according to national and local regulationsType of wires Voltage 230V / Maximum current: 100mA / Minimum 0.75mm²Notes Power supply compressor compartment is for compressor, fan, pump and controllerIn accordance with EN/IEC 61000-3-11 (1), it may be necessary to consult the distribution networkoperator to ensure that the equipment is connected only to a supply with Zsys (3) smaller than or equalto Zmax.Power supply hydraulic compartment is for the electric heater. The optional domestic warm water tankhas a separate power supply.Installer can reduce capacity of the heater from 6 to 3kW. The current is then reduced from 26 to 13A.Instructions see installation manual.Installer can reduce capacity of the heater from 6 to 3.5kW. The current is then reduced from 8.7 to5A. Instructions see installation manual.(1)European/International Technical Standard setting the limits for voltage changes , voltagefluctuations and flicker in public low-voltage supply systems for equipment with rated current <= 75A.(2) European/International Technical Standard setting the limits for harmonic currents produced byequipment connected to public low-voltage systems with input current > 16A =< 75A per phase.(3) System impedanceConditions: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)2-4 ELECTRICAL SPECIFICATIONS EDHQ011AA6W1 EDHQ014AA6W1 EDHQ016AA6W1