• Monobloc • EDLQ011-016AA6W1• Altherma TM • Monobloc1507 Wiring diagram7 - 1 Wiring diagram372TW58136-1EDLQ011-016AA6W1 A1P Printed circuit board (Main)A2P Printed circuit board (INV)A3P Printed circuit board (Noise filter)BS1∼BS4 Push button switchC1∼C4 CapacitorDS1 DIP switchE1HC Crankcase heaterE1H Bottomplate heaterF1U Fuse (T 31,5A/250V)F2U Fuse (T 31,5A/250V)F3U Fuse (T 6.3A/250V)F4U Fuse (T 6,3A/250V)F5U Fuse (T 6,3A/250V)F6U Fuse (T 6,3A/250V)F7U Fuse (T 5,0A/250V)F8U, F9U Fuse (T 1,0A/250V)H1P∼7P (A1P) Pilotlamp (service monitor - orange)HAP (A1P) Pilotlamp (service monitor - green)HAP (A2P) Pilotlamp (service monitor - green)K1M∼K2M Magnetic contactorK1R (A1P) Magnetic relay (Y1S)K1R (A2P) Magnetic relayK2R (A1P) Magnetic relay (Y2S)K3R (A1P) Magnetic relay (E1HC)L1R∼L3R ReactorL4R Reactor (For outdoor fan motor)M1C Motor (Compressor)M1F Motor (Fan) (upper)M2F Motor (Fan) (lower)PS Switching power supplyQ1DI Earth leakage protectorR1∼R4 ResistorR1T Thermistor (Air)R2T Thermistor (Discharge)R3T Thermistor (Suction)R4T Thermistor (Heat exchanger)R5T Thermistor (heat exchanger middle)R6T Thermistor (Liquid)R7T Thermistor (Fin)S1NPH Pressure sensorS1PH Pressure switch (High)V1R, V2R Power moduleV3R Diode moduleX1M Terminal stripY1E Electronic expansion valveY1S Solenoid valve (4 way valve)Y3S Solenoid valveZ1C∼Z9C Noise filterZ1F∼Z4F Noise filterOptional connectorX6A ConnectorX77A ConnectorX1Y ConnectorNotes:1 This wiring diagram only applies to the compressor module switchbox2 L: Live N:Neutral g: Field wiring3 D : Terminal strip F : Connector T : Connection R : Protective earth (screw): Connector p : Noiseless earth G : Terminal4 NOT APPLICABLE5 -6 Do not operate the unit by short-circuiting protection device S1PH7 Colors: BLK: black, RED: red, BLU: blue, WHT: white, YLW: yellow, ORG: orange, BRN: brown, GRN: green8 Confirm the method of setting the selector switches (DS1) by service manual. Factory setting of allswitches: ’’OFF’’.Power supplyOnly for E(D/B)LO*Compressor module switchboxPosition ofcompressorterminalReactor boxEl. comp. Assy(Position of elements)Option Wiring dependent onmodelTo hydromodule switchbox (8.5 Page 2Reactor terminalpositionArrow A Arrow B2TW58136-1EDLQ011-016AA6W1Outdoor unit>> See note 2 <<User interfaceOnly for *KHWS*V3OptionExample fieldsupplythermostatOptionField wiringWiring dependenton modelWire colourSee note 7For *KHWSU*V3 OptionNO valveNC valveheatingcooling 230V ACsupply from PCBOnly for *KHW*OptionOnly for *KHW*OptionOnlyfor EKSOLHWAV1OptionDomestic hotwater tankDomestic hot watertankSee note 7For *KHWSU*V3 OptionSolar pump connectionOnly for EKRP1HB& ESOLHWAV1OptionAlarm outputCooling/heatingon/off outputSolar input3 wire type(SPST)Only for EKSOLHWAV1OptionSee note 9Field wiringPCBSee note 8Domestic hotwater tankOnly for *KHWS*Z2OptionElectric heater fuseModel 6WNF1B 16AKHW kit fuseF2B 20AOnly for *KHWS*Z2OptionDomestic hot watertankNotes:1 This wiring diagram only applies to the compressor module2 Use one and same dedicated power supply compressor module switchbox, hydromodule switchbox and *KHW* option3 :Field wiring No/Nc normal open/normal closed SPST - single pole single throw.4 :Terminal strip :Connector :Terminal :Protective earth5 Do not operate the unit by short-circuiting any protection device.6 BLK: Black / WHT: White / RED: Red / BLU: Blue / PINK: Pink / YLW: YellowBRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / VIO: Violet7 For *KHWSU*V3, refer to option manual8 Option PCB works with an external 230V AC power supply unit. (N,L)9 For EKSOLHWAV1, refer to option manual10 Backupheater kW reduction, refer to installation manualOnly for*KHWE*V3OptionDomestic hot watertank Domestic hot watertankOnly for *KHWE*V3Option Only for *KHWE*Z2OptionOnly for*KHW(S/E)* OptionOnly for EKHW(S/E)*OptionOnly for EKRTETSOptionOnly for *KRTROptionOnly for *KRTWOptionPower supply E11H-E12H-E13H / E4HOnlyfor E(D/B)LO*OptionFrom compressormodule switchbox(B.7 PageA)Reduced 3.5kw ( )See note 10Standard 6kw (_)See note 10A11P : Main PCBA12P : User interface PCBA3P (*KRTW) : Thermostat (PC=power circuit)A4P (*KRTR) : Solar/remote alarm PCBA4P (EKRTR) : Receiver PCBE11H-E12H-E13H : Backup heater element 1-2-3 (6 kW)E4H : Booster heater (3kW)E5H : Switchbox heaterE6H : Expansion vessel heaterF1B : Fuse backup heaterF1T : Thermal fuse backup heaterF2B : Fuse booster heaterF8U, F9U : Fuse 1,0A F 250VFU1 : Fuse 3,15A T 250V for PCBFU2 : Fuse 5A T 250VFuS, FuR : Fuse 5A 250V for solar/remote alarm PCBK1M : Contactor backup heater stepK3M : Contactor booster heaterK4M : pump relayK5M : Contactor for backup heater all-poledisconnectionK7M : Relay for solar pumpM1P : PumpM2S : 2 way valve for cooling modeM3S : 3 way valve: floorheating/domestic hot waterPHC1 : Optocoupler input circuitQ1DI : Earth leakage protectorQ1L : Thermal protector backup heaterQ2L/Q3L : Thermal protector 1/2Booster heaterR1H (*KRTR)) : Humidity sensorR1T (*KRTW/R) : Ambient sensorR2T (EKRTETS) : External sensor (floor or ambient)R11T : Outlet water heat-exchanger thermistorR12T : Outlet water backup heater thermistorR13T : Refrigerant liquid side thermistorR14T : Inlet water thermistorR5T (*KHW*) : Domestic hot water thermistorS1L : FlowswitchS1S : Solar pumpstation relayS2S : benefit kWh rate power supply contactSS1 : DIP switchS1T : thermostat switchbox heaterS2T : thermostat expansion vessel heaterTR1 : Transformer 24V for PCBV1S, V2S : Spark suppression 1, 2X1M-X10M : Terminal stripsX2Y : Connector