serVIce MenusTimer Settings MenuThe Timer Settings Menu is also available from theCommission Unit Menu, and is described on page 34Save/Restore MenuThe Save/Restore menu can be used to save or restore theuser configured parameters as well as reset the controller backto the factory default parametersTable 40: Save/Restore MenuSave Params is an adjustable item used to save the currentparameters and configuration.Rstr Params is an adjustable item used to restore the currentparameters and configuration.Rstr Factory is an adjustable item used to restore the factoryparameters and configuration.SaveToCard is an adjustable item used to save the currentparameters and configuration to an SD card.LoadFromCard is an adjustable item used to restore thecurrent parameters and configuration from an SD card.NOTE: The controller will automatically perform a reset whenthe value of Load From Card is changed from No toYes and the enter button is pushedOperating HoursThe Operating Hours menu gives a summary of the hours ofoperation for each of the supply fans, return/exhaust fans,compressors, heating and economizer operationTable 41: Operating Hours MenuSupply Fan is a status item which gives the number of hoursthe supply fan has operatedReturn/Exhaust Fan is a status item which gives the numberof hours the return/exhaust fans have operatedCmp Cooling is a status item which indicates the number ofhours compressor cooling has operatedINV Comp is a status item which indicates the number of hoursthe inverter compressor has operatedComp 3 is a status item which indicates the number of hoursthe fixed speed compressor has operated.Heating is a status item which gives the number of hours thatthe heating mode has operatedCmp Heating is a status item which indicates the number ofhours compressor heating has operatedEconomizer is a status item which gives the number of hoursthat the economizer has operatedTnt Override is a status item which gives the number of hoursthat the unit has operated in the Tenant Override mode ofoperationDehumid is a status item which gives the number of hours thatthe dehumidification has operated.ER Wheel is a status item which gives the number of hoursthat the energy recovery wheel has operatedReheat is a status item which gives the number of hours thereheat has operatedItem DisplayName DefaultSetting Range PasswordLevelSave Params= No No/Yes 2Rstr Params= No No/Yes 2Rstr Factory= No No/Yes 2SaveToCard= No No/Yes 2LoadFromCard No No/Yes 2Item DisplayName DefaultSetting Range PasswordLevelSupply Fan= — 0–50000H 6Ret/Exh Fan= — 0–50000H 6Cmp Cooling= — 0–50000H 6INV Comp= — 0–50000H 6Comp3= — 0–50000H 6Heating= — 0–50000H 6Cmp Heating= — 0–50000H 6Economizer= — 0–50000H 6Tnt Override= — 0–50000H 6Dehumid= — 0–50000H 6ER Wheel= — 0–50000H 6Reheat= — 0–50000H 6OM 1141-3 • MICROTECH UNIT CONTROLLER 62 wwwserVIce Menus