Si04-115 General FunctionalityMain Function 251.6 Wide-angle Flaps, Diffuser, Louveres and AutoswingOutline of theactionIt can be commanded for J type by means of a user setting to select either any one desiredposition among the five-step directions of air flow adjusted on a remote controller, or Auto-swing.Although the liquid crystal display of the five-step directions of the air flow is common for themodes of Cooling·Dry/Heating as illustrated above, in fact the range of the swing angle isslightly different in every operation mode.The position a user set will be selected among the five positions calculated through thepreliminary and evenly divided into four partitions which were taken from the upper and lowerflap angle’s range limits of each mode.When Auto-swing is chosen, the flap swings in the swing range which meets the operationmode selected.Others " The vertical louver can be adjusted manually. The movable range is 60 degrees for left orright, and total 120 degrees.12345Initial (R1902)∗ Fan mode is available for the models of cooling-only.20˚45˚Heating mode0 degree based onthe horizontal line.(R1903)0˚25˚Cooling /Dry mode0 degree based onthe horizontal line.(R1904)10˚45˚0 degree based onthe horizontal line.Fan mode(R1905)