English9COMPELECTRICAL WIRING CONNECTIONOutdoor UnitTerminal BlockIndoor UnitTerminal BlockPower Supply CableCooling Unit (single phase)IMPORTANT : * The figures shown in the table are for information purpose only. They should be checked and selectedto comply with the local/national codes of regulations. This is also subject to the type of installation andconductors used.** The appropriate voltage range should be checked with label data on the unit.Interconnection cableModel FTS20JEV1KRS20JEV1KFTS25JEV1KRS25JEV1KVoltage range** 220-240V/1Ph/50Hz + !Power supply cable size* mm 2Number of conductors2.532.53Interconnection cable size* mm 2Number of conductors2.532.53Recommended time delay fuse* A 20 20There must be an all poledisconnection in the supplymains with a contact separationof at least 3mm.!N1NLAttach insulation sleeveRound crimp-style terminalElectric wireAll wires must be firmly connected.All wires must not touch the refrigerant piping, compressor or any moving parts of the fan motor.The connecting wires between the indoor unit and the outdoor unit must be clamped on the wire clamps.The power supply cord must be equivalent to H07RN-F which is the minimum requirement.Make sure no external pressure is applied to the terminal connectors and wires.Make sure all the covers are properly fixed to avoid any gap.Use round crimp-style terminal for connecting wires to the power supply terminal block. Connect the wires by matchingto the indication on terminal block. (Refer to the wiring diagram attached on the unit).•••••••Connect wires of thesame gauge to both side.Do not connect wires of thesame gauge to one side.Do not connect wiresof different gauges.Used the correct screwdriver for terminal screws tightening. Unsuitable screwdrivers can damage the screw head.Over tightening can damage the terminal screws.Do not connect wire of different gauge to same terminal.Keep wiring in an orderly manner. Prevent the wiring from obstructing other parts and the terminal box cover.••••COMPN