6Mounting Installation PlateEnsure that the wall is strong enough to withstand the weightof the unit. Otherwise, it is necessary to reinforce the wallwith plates, beams or pillars.Use the level gauge for horizontal mounting, and fix it with7 suitable screws for FTS20/25JEV1K.In case the rear piping draws out, drill a hole 65mm indiameter with a cone drill, slightly lower on the outside wall(see figure).Through thewall holeØ 65mmRecommended mounting plateretention spots (7 spots in all)190 1736131061Drain hosepositionGas pipe endLiquid pipe end 4845580 1065219404091 45Water Drainage PipingThe indoor drain pipe must be in a downward gradient forsmooth drainage. Avoid situations that are likely to causewater to leak.Mounting plateClipMark (rear side)Bottom frameFront grilleMount The Unit Onto The Installation PlateHook the indoor unit onto the upper portion of the installationplate (Engage the two hooks at the rear top of the indoor unitwith the upper edge of the installation plate). Ensure that thehooks are properly seated on the installation plate by movingit to the left and right.How To Attach The Indoor UnitHook the claws of the bottom frame to the mounting plate.How To Remove The Indoor UnitPush up the marked area (at the lower part of the front grille)to release the claws.Mounting plateInterconnectingwiresHang indoor unit’s hook here.Wire guideWhen stripping theends of interconnectingwires in advance, bindright ends of wires withinsulating tape.Recommended Mounting Plate Retention Spots AndDimensionsInsideCaulkingOutsideWall embedded pipe(Field supply)Wall hole cover(Field supply) Wall embedded pipe(Field supply)Ø 65Hole with cone drillEnd dippedinto waterWater leakingWater leaking Water leakingWrong Wrong WrongDrainWater DrainageWater RetentionCorrectMounting plateMounting platefixing screwFTS20/25JEV1KFTS20/25JEV1KAll dimensions are in mm! CAUTION• Do not install the unit at altitude over 2000m for both indoor and outdoor.