SiBE041434E Main FunctionsFunction and Control 281.12 Inverter POWERFUL OperationOutline In order to exploit the cooling and heating capacity to full extent, the air conditioner can beoperated by increasing the indoor fan rotating speed and the compressor frequency.Detail When the POWERFUL button is pressed, the fan speed and target temperature are convertedto the following states for 20 minutes.A = 60 ~ 80 rpm (depending on the model)Ex: POWERFUL operation in coolingNote: POWERFUL operation cannot be used together with ECONO, COMFORT AIRFLOW, orOUTDOOR UNIT QUIET operation.Operation mode Fan speed Target temperatureCOOL H tap + A rpm 18°CDRY Dry rotating speed + A rpm Lowered by 2.5°CHEAT H tap + A rpm 31°CFAN H tap + A rpm —AUTO Same as cooling / heating inPOWERFUL operation The target temperature iskept unchanged.(R19177)Target temp.Fan A rpm18˚CH tapSet tap20 minutesIt should be the lower limit ofcooling temperature.It counts 20 minutes alsoin the remote controller.POWERFULONPOWERFULOFFEnding condition:1. After the lapse of 20 minutes.2. Operation OFF3. POWERFUL operation is OFF.